Evidence map›Paper›PMID 24349928›Full record

ArticleMass spectrometry (Tokyo, Japan)2013

Mass resolution and mass accuracy: how much is enough?

Alan G Marshall, Greg T Blakney, Tong Chen, Nathan K Kaiser, Amy M McKenna, Ryan P Rodgers, Brian M Ruddy, Feng Xian

Abstract read
In one paragraph

Article in Mass spectrometry (Tokyo, Japan), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alan G MarshallDepartment of Chemistry & Biochemistry, Florida State University ; Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.
Greg T BlakneyIon Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.
Tong ChenDepartment of Chemistry & Biochemistry, Florida State University.
Nathan K KaiserIon Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.
Amy M McKennaIon Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.
Ryan P RodgersDepartment of Chemistry & Biochemistry, Florida State University ; Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.
Brian M RuddyDepartment of Chemistry & Biochemistry, Florida State University.
Feng XianIon Cyclotron Resonance Program, National High Magnetic Field Laboratory, Florida State University.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate mass measurement requires the highest possible mass resolution, to ensure that only a single elemental composition contributes to the mass spectral peak in question. Although mass resolution is conventionally defined as the closest distinguishable separation between two peaks of equal height and width, the required mass resolving power can be ∼10× higher for equal width peaks whose peak height ratio is 100 : 1. Ergo, minimum resolving power requires specification of maximum dynamic range, and is thus 10-100× higher than the conventional definition. Mass resolving power also depends on mass-to-charge ratio. Mass accuracy depends on mass spectral signal-to-noise ratio and digital resolution. Finally, the reliability of elemental composition assignment can be improved by resolution of isotopic fine structure. Thus, the answer to the question of "how much is enough mass resolving power" requires that one first specify S/N ratio, dynamic range, digital resolution, mass-to-charge ratio, and (if available) isotopic fine structure. The highest available broadband mass resolving power and mass accuracy is from Fourier transform ion cyclotron resonance mass spectrometry. Over the past five years, FT-ICR MS mass accuracy has improved by about an order of magnitude, based on higher magnetic field strength, conditional averaging of time-domain transients, better mass calibration (spectral segmentation; inclusion of a space charge term); radially dispersed excitation; phase correction to yield absorption-mode display; and new ICR cell segmentation designs.

Indexed as

Fourier transformFTMSion cyclotron resonanceisotopic fine structure

Identifiers

PMID24349928
PMCPMC3809961

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.