Evidence map›Paper›PMID 24334301›Full record

ArticlePhysics in medicine and biology2014

Optimization of K-edge imaging for vulnerable plaques using gold nanoparticles and energy resolved photon counting detectors: a simulation study.

Yahya Alivov, Pavlo Baturin, Huy Q Le, Justin Ducote, Sabee Molloi

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 20 citations in OpenAlex.

  1. XCIST-an open access x-ray/CT simulation toolkit.Physics in medicine and biology · 2022
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yahya Alivov
Pavlo Baturin
Huy Q Le
Justin Ducote
Sabee Molloi
University of California, Irvine · US

Funding

Quantification of coronary calcium mass by dual energy fluoroscopyR01HL083295 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI MOLLOI, SABEE · 2007 to 2009
$1.1M
Fractional flow reserve measurement based on coronary angiographic imagesR01HL089941 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI MOLLOI, SABEE · 2009 to 2010
$867k
NHLBI NIH HHS R01 HL083295NHLBI NIH HHS R01 HL089941
6 · The paper itself

Abstract

We investigated the effect of different imaging parameters, such as dose, beam energy, energy resolution and the number of energy bins, on the image quality of K-edge spectral computed tomography (CT) of gold nanoparticles (GNP) accumulated in an atherosclerotic plaque. A maximum likelihood technique was employed to estimate the concentration of GNP, which served as a targeted intravenous contrast material intended to detect the degree of the plaque's inflammation. The simulation studies used a single-slice parallel beam CT geometry with an x-ray beam energy ranging between 50 and 140 kVp. The synthetic phantoms included small (3 cm in diameter) cylinder and chest (33 × 24 cm(2)) phantoms, where both phantoms contained tissue, calcium and gold. In the simulation studies, GNP quantification and background (calcium and tissue) suppression tasks were pursued. The x-ray detection sensor was represented by an energy resolved photon counting detector (e.g., CdZnTe) with adjustable energy bins. Both ideal and more realistic (12% full width at half maximum (FWHM) energy resolution) implementations of the photon counting detector were simulated. The simulations were performed for the CdZnTe detector with a pixel pitch of 0.5-1 mm, which corresponds to a performance without significant charge sharing and cross-talk effects. The Rose model was employed to estimate the minimum detectable concentration of GNPs. A figure of merit (FOM) was used to optimize the x-ray beam energy (kVp) to achieve the highest signal-to-noise ratio with respect to the patient dose. As a result, the successful identification of gold and background suppression was demonstrated. The highest FOM was observed at the 125 kVp x-ray beam energy. The minimum detectable GNP concentration was determined to be approximately 1.06 µmol mL(-1) (0.21 mg mL(-1)) for an ideal detector and about 2.5 µmol mL(-1) (0.49 mg mL(-1)) for a more realistic (12% FWHM) detector. The studies show the optimal imaging parameters at the lowest patient dose using an energy resolved photon counting detector to image GNP in an atherosclerotic plaque.

Indexed as

Metal NanoparticlesPhotonsCadmiumGoldModels, TheoreticalPhantoms, ImagingPlaque, AtheroscleroticPolymethyl MethacrylateScintillation CountingSignal-To-Noise RatioTelluriumTomography, X-Ray ComputedZincCadmiumCdZnTeGoldPolymethyl MethacrylateTelluriumZinc

Identifiers

PMID24334301
PMCPMC3962835
OpenAlexW2074073563

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.