ArticleBiosensors & bioelectronics2014
Stretchable electrochemical impedance sensors for intravascular detection of lipid-rich lesions in New Zealand White rabbits.
Article in Biosensors & bioelectronics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Machine learning-directed electrical impedance tomography to predict metabolically vulnerable plaques.Bioengineering & translational medicine · 2024Article
- A self-assembled implantable microtubular pacemaker for wireless cardiac electrotherapy.Science advances · 2023Article
- 3-Dimensional electrical impedance spectroscopy forSensors and actuators. B, Chemical · 2022Article
- Progress of Wearable and Flexible Electrochemical Biosensors With the Aid of Conductive Nanomaterials.Frontiers in bioengineering and biotechnology · 2021Review
- Biosensors for Detection of Human Placental Pathologies: A Review of Emerging Technologies and Current Trends.Translational research : the journal of laboratory and clinical medicine · 2019Review
- Flow-Responsive Vascular Endothelial Growth Factor Receptor-Protein Kinase C Isoform Epsilon Signaling Mediates Glycolytic Metabolites for Vascular Repair.Antioxidants & redox signaling · 2018Article
- 3-D Electrochemical Impedance Spectroscopy Mapping of Arteries to Detect Metabolically Active but Angiographically Invisible Atherosclerotic Lesions.Theranostics · 2017Article
- Ultrasonic Transducer-Guided Electrochemical Impedance Spectroscopy to Assess Lipid-Laden Plaques.Sensors and actuators. B, Chemical · 2016Article
- Two-Point Stretchable Electrode Array for Endoluminal Electrochemical Impedance Spectroscopy Measurements of Lipid-Laden Atherosclerotic Plaques.Annals of biomedical engineering · 2016Article
- Power Approaches for Implantable Medical Devices.Sensors (Basel, Switzerland) · 2015Review
- Electrical and Mechanical Strategies to Enable Cardiac Repair and Regeneration.IEEE reviews in biomedical engineering · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
Abstract
Flexible electronics have enabled catheter-based intravascular sensing. However, real-time interrogation of unstable plaque remains an unmet clinical challenge. Here, we demonstrate the feasibility of stretchable electrochemical impedance spectroscopy (EIS) sensors for endoluminal investigations in New Zealand White (NZW) rabbits on diet-induced hyperlipidemia. A parylene C (PAC)-based EIS sensor mounted on the surface of an inflatable silicone balloon affixed to the tip of an interrogating catheter was deployed (1) on the explants of NZW rabbit aorta for detection of lipid-rich atherosclerotic lesions, and (2) on live animals for demonstration of balloon inflation and EIS measurements. An input peak-to-peak AC voltage of 10 mV and sweeping-frequency from 300 kHz to 100 Hz were delivered to the endoluminal sites. Balloon inflation allowed EIS sensors to be in contact with endoluminal surface. In the oxidized low-density-lipoprotein (oxLDL)-rich lesions from explants of fat-fed rabbits, impedance magnitude increased significantly by 1.5-fold across the entire frequency band, and phase shifted ~5° at frequencies below 10 kHz. In the lesion-free sites of the normal diet-fed rabbits, impedance magnitude increased by 1.2-fold and phase shifted ~5° at frequencies above 30 kHz. Thus, we demonstrate the feasibility of stretchable intravascular EIS sensors for identification of lipid rich lesions, with a translational implication for detecting unstable lesions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.