ArticleThe Journal of thoracic and cardiovascular surgery2014
Nonphysiologic blood flow triggers endothelial and arterial remodeling in vivo: implications for novel left ventricular assist devices with a peripheral anastomosis.
Article in The Journal of thoracic and cardiovascular surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 13 citations in OpenAlex.
- Effects of Pulsatility on Arterial Endothelial and Smooth Muscle Cells.Cells, tissues, organs · 2023Article
- Biomarkers in Patients with Left Ventricular Assist Device: An Insight on Current Evidence.Biomolecules · 2022Review
- Increased pulsatility index is associated with adverse outcomes in left ventricular assist device recipients.ESC heart failure · 2021Article
- Carotid artery structure and hemodynamics and their association with adverse vascular events in left ventricular assist device patients.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2021Article
- Robotic-assisted implantation of ventricular assist device after sternectomy and pectoralis muscle flap.ASAIO journal (American Society for Artificial Internal Organs : 1992)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
objectivesLess invasive circulatory support devices have been developed that require anastomosis to a peripheral artery. The Symphony Heart Assist System (Abiomed, Inc, Danvers, Mass) is a volume-displacement pump sewn to the subclavian artery to provide partial circulatory support. The surgical configuration produces nonphysiologic blood pressure and bidirectional flow in the subclavian artery. Our objective was to identify effects of altered hemodynamics on arterial structure and function.
methodsIn calves (n = 23; 80-100 kg), the Symphony pump was sewn end-to-side to the carotid artery. Acutely, carotid blood pressure and flow were recorded to evaluate hemodynamic changes. After medium-term support (1-4 weeks), carotid artery was studied. Histologic and molecular assays evaluated architectural changes. Quantitative real-time polymerase chain reaction evaluated gene expression of matrix metalloproteinase (MMP)-2, MMP-9, and connective tissue growth factor. In vitro carotid arterial-ring studies evaluated physiologic responses.
resultsDuring Symphony support, carotid arterial pressure was 200/15 mm Hg. Antegrade flow increased significantly (P < .05) from 1.40 ± 0.32 to 4.29 ± 0.33 L/min. Flow during native cardiac diastole reversed completely from 0.25 ± 0.05 to -4.15 ± 0.38 L/min in carotid artery proximal to the anastomosis. After medium-term support, the carotid artery was significantly dilated with significantly thinner tunica media and thicker tunica adventitia than in control carotid arteries. MMP-9 gene expression decreased significantly, connective tissue growth factor gene expression increased significantly, and collagen, elastin, and total extracellular matrix increased significantly. Endothelial cells were significantly hypertrophied and produced significantly more von Willebrand factor. Endothelial apoptosis increased significantly. Platelet-endothelial interactions decreased significantly. Endothelial-independent contraction decreased significantly, whereas endothelial-dependent relaxation increased modestly.
conclusionsAssisted circulation with a left ventricular assist device triggered arterial remodeling that allowed a peripheral artery to accommodate the altered hemodynamics of a novel partial-support pump. Further delineation of remodeling pathways may be of significance for the emerging field of partial circulatory support.