Evidence map›Paper›PMID 24332190›Full record

ArticleThe Journal of thoracic and cardiovascular surgery2014

Nonphysiologic blood flow triggers endothelial and arterial remodeling in vivo: implications for novel left ventricular assist devices with a peripheral anastomosis.

Carlo R Bartoli, Paul A Spence, Thorsten Siess, Daniel H Raess, Steven C Koenig, Robert D Dowling

Abstract read
In one paragraph

Article in The Journal of thoracic and cardiovascular surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Carotid artery structure and hemodynamics and their association with adverse vascular events in left ventricular assist device patients.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2021
    Article
  5. Robotic-assisted implantation of ventricular assist device after sternectomy and pectoralis muscle flap.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Carlo R BartoliDivision of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pa; MD/PhD Program, University of Louisville School of Medicine, Louisville, Ky. Electronic address: carlo.bartoli@uphs.upenn.edu.
Paul A SpenceSCR Inc, Louisville, Ky.
Thorsten SiessAbiomed, Inc, Danvers, Mass.
Daniel H RaessAbiomed, Inc, Danvers, Mass.
Steven C KoenigDepartment of Bioengineering, University of Louisville, Louisville, Ky.
Robert D DowlingDowling Consulting, PSC, Louisville, Ky.
Abiomed (United States) · USUniversity of Louisville · USUniversity of Pennsylvania · US

Funding

Portable pneumatic driver for counterpulsation therapyR44HL088760 · NHLBI · SCR, INC. · PI SPENCE, PAUL A · 2009 to 2010
$1.6M
Development of a Counterpulsation Therapy DeviceR44HL083586 · NHLBI · SCR, INC. · PI SPENCE, PAUL A · 2008 to 2009
$1.4M
Counterpulsation Device with Integrated ECG SensingR43HL102981 · NHLBI · SCR, INC. · PI DOWLING, ROBERT D. · 2010 to 2010
$239k
NHLBI NIH HHS 2R44HL083586-02A1NHLBI NIH HHS 2R44HL088760-02NHLBI NIH HHS R43 HL102981NHLBI NIH HHS R43HL102981NHLBI NIH HHS R44 HL083586NHLBI NIH HHS R44 HL088760
6 · The paper itself

Abstract

objectivesLess invasive circulatory support devices have been developed that require anastomosis to a peripheral artery. The Symphony Heart Assist System (Abiomed, Inc, Danvers, Mass) is a volume-displacement pump sewn to the subclavian artery to provide partial circulatory support. The surgical configuration produces nonphysiologic blood pressure and bidirectional flow in the subclavian artery. Our objective was to identify effects of altered hemodynamics on arterial structure and function.

methodsIn calves (n = 23; 80-100 kg), the Symphony pump was sewn end-to-side to the carotid artery. Acutely, carotid blood pressure and flow were recorded to evaluate hemodynamic changes. After medium-term support (1-4 weeks), carotid artery was studied. Histologic and molecular assays evaluated architectural changes. Quantitative real-time polymerase chain reaction evaluated gene expression of matrix metalloproteinase (MMP)-2, MMP-9, and connective tissue growth factor. In vitro carotid arterial-ring studies evaluated physiologic responses.

resultsDuring Symphony support, carotid arterial pressure was 200/15 mm Hg. Antegrade flow increased significantly (P < .05) from 1.40 ± 0.32 to 4.29 ± 0.33 L/min. Flow during native cardiac diastole reversed completely from 0.25 ± 0.05 to -4.15 ± 0.38 L/min in carotid artery proximal to the anastomosis. After medium-term support, the carotid artery was significantly dilated with significantly thinner tunica media and thicker tunica adventitia than in control carotid arteries. MMP-9 gene expression decreased significantly, connective tissue growth factor gene expression increased significantly, and collagen, elastin, and total extracellular matrix increased significantly. Endothelial cells were significantly hypertrophied and produced significantly more von Willebrand factor. Endothelial apoptosis increased significantly. Platelet-endothelial interactions decreased significantly. Endothelial-independent contraction decreased significantly, whereas endothelial-dependent relaxation increased modestly.

conclusionsAssisted circulation with a left ventricular assist device triggered arterial remodeling that allowed a peripheral artery to accommodate the altered hemodynamics of a novel partial-support pump. Further delineation of remodeling pathways may be of significance for the emerging field of partial circulatory support.

Indexed as

Heart-Assist DevicesHemodynamicsAnastomosis, SurgicalAnimalsApoptosisArterial PressureBlood Flow VelocityCardiac Surgical ProceduresCarotid ArteriesCattleConnective Tissue Growth FactorDilatation, PathologicEndothelium, VascularGene Expression RegulationMaleMatrix Metalloproteinase 2Connective Tissue Growth FactorMatrix Metalloproteinase 2Matrix Metalloproteinase 9RNA, Messenger

Identifiers

PMID24332190
PMCPMC4048802
OpenAlexW1978669603

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.