Evidence map›Paper›PMID 24328221›Full record

ArticleAnalytical chemistry2014

Refractive index-based detection of gradient elution liquid chromatography using chip-integrated microring resonator arrays.

James H Wade, Ryan C Bailey

Abstract read
In one paragraph

Article in Analytical chemistry, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Flow Injection-Based Refractive Index Sensing with a SiACS applied optical materials · 2025
    Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Recent Advances in Microscale Western Blotting.Analytical methods : advancing methods and applications · 2016
    Article
  7. Applications of Optical Microcavity Resonators in Analytical Chemistry.Annual review of analytical chemistry (Palo Alto, Calif.) · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

James H WadeDepartment of Chemistry, University of Illinois at Urbana-Champaign , 600 S. Mathews Ave., Urbana, IL 61801, United States.
Ryan C Bailey

Funding

Meso-plex miRNA and protein profiling for cancer diagnostics using chip-integrateR33CA177462 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI BAILEY, RYAN C, JOHNSON, MARK D · 2013 to 2015
$984k
NCI NIH HHS CA177462-01NCI NIH HHS R33 CA177462
6 · The paper itself

Abstract

Refractive index-based sensors offer attractive characteristics as nondestructive and universal detectors for liquid chromatographic separations, but a small dynamic range and sensitivity to minor thermal perturbations limit the utility of commercial RI detectors for many potential applications, especially those requiring the use of gradient elutions. As such, RI detectors find use almost exclusively in sample abundant, isocratic separations when interfaced with high-performance liquid chromatography. Silicon photonic microring resonators are refractive index-sensitive optical devices that feature good sensitivity and tremendous dynamic range. The large dynamic range of microring resonators allows the sensors to function across a wide spectrum of refractive indices, such as that encountered when moving from an aqueous to organic mobile phase during a gradient elution, a key analytical advantage not supported in commercial RI detectors. Microrings are easily configured into sensor arrays, and chip-integrated control microrings enable real-time corrections of thermal drift. Thermal controls allow for analyses at any temperature and, in the absence of rigorous temperature control, obviates extended detector equilibration wait times. Herein, proof of concept isocratic and gradient elution separations were performed using well-characterized model analytes (e.g., caffeine, ibuprofen) in both neat buffer and more complex sample matrices. These experiments demonstrate the ability of microring arrays to perform isocratic and gradient elutions under ambient conditions, avoiding two major limitations of commercial RI-based detectors and maintaining comparable bulk RI sensitivity. Further benefit may be realized in the future through selective surface functionalization to impart degrees of postcolumn (bio)molecular specificity at the detection phase of a separation. The chip-based and microscale nature of microring resonators also make it an attractive potential detection technology that could be integrated within lab-on-a-chip and microfluidic separation devices.

Indexed as

Chromatography, LiquidMicrofluidic Analytical TechniquesPharmaceutical PreparationsRefractometryPharmaceutical Preparations

Identifiers

PMID24328221
PMCPMC3950336

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.