ArticleAnnals of surgical innovation and research2013
Rationale, bench testing and in vivo evaluation of a novel 5 mm laparoscopic vessel sealing device with homogeneous pressure distribution in long instrument jaws.
Article in Annals of surgical innovation and research, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Decellularization of various tissues and organs through chemical methods.Tissue & cell · 2024Review
- Comparison of Two Radiofrequency Vessel-Sealing Device for Laparoscopic Ovariectomy in African Lionesses (Panthera Leo).Animals : an open access journal from MDPI · 2022Article
- Ex-Vivo Evaluation of "First Tip Closing" Radiofrequency Vessel Sealing Devices for Swine Small Intestinal Transection.Veterinary sciences · 2022Article
- Swine Small Intestine Sealing Performed by Different Vessel Sealing Devices: Ex-Vivo Test.Veterinary sciences · 2021Article
- Effectiveness of a bipolar vessel sealant device for ovariohysterectomy in cats with pyometra.Journal of feline medicine and surgery · 2018Article
- Evaluation and Comparison of Contemporary Energy-Based Surgical Vessel Sealing Devices.Journal of endourology · 2018Article
- Implementation of a novel efficacy score to compare sealing and cutting devices in a porcine model.Surgical endoscopy · 2018Article
- Consistency and sealing of advanced bipolar tissue sealers.Medical devices (Auckland, N.Z.) · 2015Article
- Partial lung lobectomy with the CaimanOpen veterinary journalReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn 1998, an electrothermal bipolar vessel sealing (EBVS) system was introduced and quickly became an integral component of the surgical armamentarium in various surgical specialties. Currently available EBVS instruments use a scissor-like jaw configuration and closing mechanism, which causes decreasing compression pressure from the proximal to the distal end of the jaws. A new EBVS system is described here which utilizes a different instrument jaw configuration and closing mechanism to enable a more homogeneous pressure distribution despite longer instrument jaws.
methodsResults of jaw pressure distribution measurements as well as sealing experiments with subsequent burst pressure measurements ex vivo on bovine uterine arteries are demonstrated. Furthermore, an in vivo evaluation of the new EBVS system in a canine and porcine model including histological examination is presented.
resultsThe device revealed an even pressure distribution throughout the whole jaw length. The ex vivo burst pressure measurements revealed high average burst pressures, above 300 mmHg, independent of the outer diameter (1 to 7 mm) of the tested vessels. Histological evaluation of sealed vessels 21 days postoperatively demonstrated sealed and fused vessels without adjacent tissue damage.
conclusionsThe even pressure distribution leading to a sufficient tissue sealing in combination with the novel closing mechanism and extended jaw length differentiates the novel device from other available EBVS systems. This might offer a reduction of the overall procedure time, which should be further evaluated in a clinical study.
Identifiers
What OpenQuestion holds
Registered trials