Evidence map›Paper›PMID 24322995›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2014

Quality of patient positioning during cerebral tomotherapy irradiation using different mask systems.

C Leitzen, T Wilhelm-Buchstab, S Garbe, C Lütter, T Müdder, B Simon, H H Schild, H Schüller

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

C LeitzenRadiologische Klinik, FE Strahlentherapie, Universitätsklinik Bonn, Sigmund-Freud-Str. 25, 53105, Bonn, Germany, christina.leitzen@ukb.uni-bonn.de.
T Wilhelm-Buchstab
S Garbe
C Lütter
T Müdder
B Simon
H H Schild
H Schüller
Universitätsklinik für Strahlentherapie · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposePatient immobilization during brain tumor radiotherapy is achieved by employing different mask systems. Two innovative mask systems were developed to minimize the problems of claustrophobic patients. Our aim was to evaluate whether the quality of patient immobilization using the new mask systems was equivalent to the standard mask system currently in use. MATERIAL AND

methodsThirty-three patients with cerebral target volumes were irradiated using the Hi-Art II tomotherapy system between 2010 and 2012. Each group of 11 patients was fitted with one of the two new mask systems (Crystal® or Open Face® mask, Orfit) or the standard three-point mask (Raycast®-HP, Orfit) and a total of 557 radiotherapy fractions were evaluated. After positioning was checked by MV-CT, the necessary table adjustments were noted. Data were analyzed by comparing the groups, and safety margins were calculated for nonimage-guided irradiation.

resultsThe mean values of the table adjustments were: (a) lateral (mm): - 0.22 (mask 1, standard deviation (σ): 2.15); 1.1 (mask 2, σ: 2.4); - 0.64 (mask 3, σ: 2.9); (b) longitudinal (mm): - 1 (mask 1, σ: 2.57); - 0.5 (mask 2, σ: 4.7); - 1.22 (mask 3, σ: 2.52); (c) vertical (mm): 0.62 (mask 1, σ: 0.63); 1.2 (mask 2, σ: 1.0); 0.57 (mask 3, σ: 0.28); (d) roll: 0.35° (mask 1, σ: 0.75); 0° (mask 2, σ: 0.8); 0.02° (mask 3, σ: 1.12). The outcomes suggest necessary safety margins of 5.49-7.38 mm (lateral), 5.4-6.56 mm (longitudinal), 0.82-3.9 mm (vertical), and 1.93-4.5° (roll). There were no significant differences between the groups.

conclusionsThe new mask systems improve patient comfort while providing consistent patient positioning.

Indexed as

Brain NeoplasmsEquipment DesignEquipment Failure AnalysisGermanyHumansImmobilizationMasksPatient PositioningRadiographyReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID24322995
OpenAlexW15621801

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.