Evidence map›Paper›PMID 24317438›Full record

ArticleLangenbeck's archives of surgery2014

A novel adaptation of laparoscopic Tenckhoff catheter insertion technique to enhance catheter stability and function in automated peritoneal dialysis.

Clemens M Meier, Aaron Poppleton, Danilo Fliser, Matthias Klingele

Abstract read
PubMed Publisher
In one paragraph

Article in Langenbeck's archives of surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 95% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Clemens M MeierDepartment of General, Visceral, Vascular and Paediatric Surgery, Saarland University Hospital, 66421, Homburg, Saar, Germany, clemens-magnus.meier@uks.eu.
Aaron Poppleton
Danilo Fliser
Matthias Klingele
Saarland University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAutomated peritoneal dialysis (APD) normally takes place overnight. Maintaining a stable PD catheter position, independent of body position, omental wrapping or catheter displacement secondary to bowel movements is essential in maintaining effective catheter function.

methodsWe developed a new procedure of catheter placement through combining and adapting several previously described operative techniques including laparoscopic placement of a curled double cuff Tenckhoff catheter with subcutaneous tunneling superior to the rectus sheet, an oblique course through the abdominal wall, deep entry into the pelvic peritoneum and directed placement of the curled tip within the pouch of Douglas. Retrospective analysis of catheter function was conducted, evaluating catheter position, function, complication rate and catheter survival against findings for current insertion techniques described within literature.

resultsBetween March 2009 and November 2011, 54 patients underwent PD catheter insertion. The observation period was an average of 343 ± 273 days. All patients received abdominal plain film showing optimal catheter position in 89 %. Reported catheter function was very good in 85.2 %, with no or few alarms per week during APD, moderate in 9.3 % with occasional minor dysfunctions (≤ 2 alarms per night), and poor in 5.6 %, with regular alarm disturbance. In one case, primary dysfunction led to catheter replacement. At completion, stable catheter function with occasional minor dysfunction was achieved in 52 of 54 cases. Catheter-related complications (leakage, hydrocele formation, infection and need for replacement) were observed in 14.8 %. At the end of the observation period, 55.6 % of catheters remained in use. Patient dropout occurred through death (18.5 %), renal transplantation (7.4 %), renal recovery (1.9 %), removal secondary to infection or dysfunction (9.3 %) and conversion to HD due to poor dialysis quality (7.4 %).

conclusionThe above technique combines and optimises previously described laparoscopic catheter implantation techniques, allowing increased catheter stability resulting in an undisturbed catheter function suitable for APD.

Indexed as

Catheters, IndwellingAdultAgedAged, 80 and overDevice RemovalEquipment FailureFemaleHumansLaparoscopyMaleMiddle AgedPatient DropoutsPeritoneal DialysisPneumoperitoneum, ArtificialPostoperative ComplicationsRetrospective Studies

Identifiers

PMID24317438
OpenAlexW1969445036

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.