Evidence map›Paper›PMID 24301336›Full record

ArticleMagnetic resonance in medicine2014

Octopus visual system: a functional MRI model for detecting neuronal electric currents without a blood-oxygen-level-dependent confound.

Xia Jiang, Hanbing Lu, Shuichi Shigeno, Li-Hai Tan, Yihong Yang, Clifton W Ragsdale, Jia-Hong Gao

Open access · bronzeAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Can MRI Be Used as a Sensor to Record Neural Activity?Sensors (Basel, Switzerland) · 2023
    Review
  2. Diffusion MRI Connections in the Octopus Brain.Experimental neurobiology · 2022
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Xia JiangBrain Research Imaging Center and Department of Radiology, University of Chicago, Chicago, Illinois, USA.
Hanbing Lu
Shuichi Shigeno
Li-Hai Tan
Yihong Yang
Clifton W Ragsdale
Jia-Hong Gao
National Institute on Drug Abuse · USUniversity of Chicago · USBrain Research Foundation · USChinese Institute for Brain Research · CNUniversity of Hong Kong · HK

Funding

Re-Engineering Translational Research at the University of ChicagoUL1TR000430 · NCATS · UNIVERSITY OF CHICAGO · PI SOLWAY, JULIAN · 2012 to 2016
$20.2M
Animal MRI/MRS Methodological Development for Drug Addiction ApplicationsZIADA000545 · NIDA · NATIONAL INSTITUTE ON DRUG ABUSE · PI YANG, YIHONG · 2009 to 2020
$10.2M
CRCNS: Development &Optimization of Magnetic Source MRIR01EB004753 · NIBIB · UNIVERSITY OF TEXAS HLTH SCI CTR SAN ANT · PI GAO, JIA-HONG · 2004 to 2006
$661k
In Vivo Measurements of Physiologically-evoked Neuronal CurrentsR21EB015023 · NIBIB · UNIVERSITY OF CHICAGO · PI KARCZMAR, GREGORY S. · 2012 to 2013
$410k
NCATS NIH HHS UL1 TR000430NIBIB NIH HHS R01 EB004753NIBIB NIH HHS R01EB015023NIBIB NIH HHS R21EB004753NIBIB NIH HHS R21 EB015023
6 · The paper itself

Abstract

purposeDespite the efforts that have been devoted to detecting the transient magnetic fields generated by neuronal firing, the conclusion that a functionally relevant signal can be measured with MRI is still controversial. For human studies of neuronal current MRI (nc-MRI), the blood-oxygen-level-dependent (BOLD) effect remains an irresolvable confound. For tissue studies where hemoglobin is removed, natural sensory stimulation is not possible. This study investigates the feasibility of detecting a physiologically induced nc-MRI signal in vivo in a BOLD-free environment.

methodsThe cephalopod mollusc Octopus bimaculoides has vertebrate-like eyes, large optic lobes (OLs), and blood that does not contain hemoglobin. Visually evoked potentials were measured in the octopus retina and OL by electroretinogram and local field potential. nc-MRI scans were conducted at 9.4 Tesla to capture these activities.

resultsElectrophysiological recording detected strong responses in the retina and OL in vivo; however, nc-MRI failed to demonstrate any statistically significant signal change with a detection threshold of 0.2° for phase and 0.2% for magnitude. Experiments in a dissected eye-OL preparation yielded similar results.

conclusionThese findings in a large hemoglobin-free nervous system suggest that sensory evoked neuronal magnetic fields are too weak for direct detection with current MRI technology.

Indexed as

AnimalsEcho-Planar ImagingElectroretinographyEvoked Potentials, VisualFemaleImage Processing, Computer-AssistedMagnetic Resonance ImagingOctopodiformesPhotic StimulationRetinacephalopodelectroretinogramfunctional MRIlocal field potentialoptic loberetina

Identifiers

PMID24301336
PMCPMC4041854
OpenAlexW1962494510

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.