Optimal delivery of aerosols to infants during mechanical ventilation.

P Worth Longest, Mandana Azimi, Michael Hindle

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Journal of aerosol medicine and pulmonary drug delivery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
1.4field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs.Journal of aerosol medicine and pulmonary drug delivery · 2019
    Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

P Worth Longest1 Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University , Richmond, VA.
Mandana Azimi
Michael Hindle
Virginia Commonwealth University · US

Funding

Nanoaerosols from Wick Electrospray for Improved Drug Delivery to InfantsR21HD073728 · NICHD · VIRGINIA COMMONWEALTH UNIVERSITY · PI LONGEST, P. WORTH · 2012 to 2013
$376k
NICHD NIH HHS R21HD073728
6 · The paper itself

Abstract

purposeThe objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery.

methodsIn vitro experiments used a vibrating mesh nebulizer and evaluated drug deposition fraction and emitted dose through ventilation circuits containing either a commercial (CM) or new streamlined (SL) wye connector and 3-mm endotracheal tube (ETT) for aerosols with mass median aerodynamic diameters of 880 nm, 1.78 μm, and 4.9 μm. The aerosol was released into the circuit either over the full inhalation cycle (T1 delivery) or over the first half of inhalation (T2 delivery). Validated computational fluid dynamics (CFD) simulations and whole-lung model predictions were used to assess lung deposition and exhaled dose during cyclic ventilation.

resultsIn vitro experiments at a steady-state tracheal flow rate of 5 L/min resulted in 80-90% transmission of the 880-nm and 1.78-μm aerosols from the ETT. Based on CFD simulations with cyclic ventilation, the SL wye design reduced depositional losses in the wye by a factor of approximately 2-4 and improved lung delivery efficiencies by a factor of approximately 2 compared with the CM device. Delivery of the aerosol over the first half of the inspiratory cycle (T2) reduced exhaled dose from the ventilation circuit by a factor of 4 compared with T1 delivery. Optimal lung deposition was achieved with the SL wye connector and T2 delivery, resulting in 45% and 60% lung deposition for optimal polydisperse (∼1.78 μm) and monodisperse (∼2.5 μm) particle sizes, respectively.

conclusionsOptimization of selected factors and use of a new SL wye connector can substantially increase the lung delivery efficiency of medical aerosols to infants from current values of <1-10% to a range of 45-60%.

Indexed as

Equipment DesignModels, BiologicalAerosolsDrug Delivery SystemsHumansHydrodynamicsInfantInfant, NewbornInhalationIntubation, IntratrachealIn Vitro TechniquesLungParticle SizeRespiration, ArtificialTime FactorsAerosolsaerosolsCFD simulationsmechanical ventilationMonte Carlo modelingnebulizationneonaterespiratory drug deliverystreamlined wye

Identifiers

PMID24299500
PMCPMC4227441
OpenAlexW2318308722

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.