Evidence map›Paper›PMID 24299024›Full record

SynthesisScandinavian journal of trauma, resuscitation and emergency medicine2013

The measurement of tissue interface pressures and changes in jugular venous parameters associated with cervical immobilisation devices: a systematic review.

Alison Sparke, Sarah Voss, Jonathan Benger

Open access · goldAbstract readSystematic Review
In one paragraph

Synthesis in Scandinavian journal of trauma, resuscitation and emergency medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Observational
  8. C-spine clearance in poly-trauma patients: A narrative review.Journal of clinical orthopaedics and trauma · 2021
    Article
  9. Review
  10. Effectiveness of orthoses for treatment in patients with spinal pain.Yeungnam University journal of medicine · 2020
    Article
  11. Cervical collars and immobilisation: A South African best practice recommendation.African journal of emergency medicine : Revue africaine de la medecine d'urgence · 2017
    Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Alison Sparke
Sarah VossResearch Fellow in Emergency Care, Faculty of Health and Life Sciences, University of the West of England, Bristol, UK. sarah.voss@uwe.ac.uk.
Jonathan Benger
University of the West of England · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cervical immobilisation is commonly applied following trauma, particularly blunt head injury, but current methods of immobilisation are associated with significant complications. Semi-rigid disposable cervical collars are known to cause pressure ulcers, and impede effective airway management. These collars may also exacerbate a head injury by increasing intracranial pressure as a result of external compression of the jugular veins. There is a clear imperative to find ways of effectively immobilising the cervical spine whilst minimising complications, and any assessment of existing or new devices should include a standardized approach to the measurement of tissue interface pressures and their effect on jugular venous drainage from the brain. This systematic review summarises the research methods and technologies that have been used to measure tissue interface pressure and assess the jugular vein in the context of cervical immobilisation devices. 27 papers were included and assessed for quality. Laboratory investigations and biomechanical studies have gradually given way to methods that more accurately reflect clinical care. There are numerous accounts of skin ulceration associated with cervical collars, but no standardised approach to measuring tissue interface pressure. It is therefore difficult to compare studies and devices, but a pressure of less than 30 mmHg appears desirable. Cervical collars have been shown to have a compressive effect on the jugular veins, but it is not yet certain that this is the cause of the increased intracranial pressure observed in association with cervical collar use. This is the first review of its type. It will help guide further research in this area of trauma care, and the development and testing of new cervical immobilisation devices.

Indexed as

Airway ManagementCervical VertebraeHumansImmobilizationJugular VeinsPressureRegional Blood Flow

Identifiers

PMID24299024
PMCPMC4222127
OpenAlexW2100341202

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.