SynthesisScandinavian journal of trauma, resuscitation and emergency medicine2013
The measurement of tissue interface pressures and changes in jugular venous parameters associated with cervical immobilisation devices: a systematic review.
Synthesis in Scandinavian journal of trauma, resuscitation and emergency medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 27 citations in OpenAlex.
- A Benchtop Evaluation of Cervical Collar Design and Strap Tension.Medical devices (Auckland, N.Z.) · 2026Article
- Cervical Oculopathy: The Cervical Spine Etiology of Visual Symptoms and Eye Diseases-A Hypothesis Exploring Mechanisms Linking the Neck and the Eye.Diagnostics (Basel, Switzerland) · 2025Article
- Spinal Motion Restriction for Possible Traumatic Cervical Spine Injury: A Scoping Review.Cureus · 2025Review
- The ligamentous cervical instability etiology of human disease from the forward head-facedown lifestyle: emphasis on obstruction of fluid flow into and out of the brain.Frontiers in neurology · 2024Article
- Adverse Events Relating to Prolonged Hard Collar Immobilisation: A Systematic Review and Meta-Analysis.Global spine journal · 2022Review
- Clinical significance of "positive" cervical spine MRI findings following a negative CT.Emergency radiology · 2022Article
- Risk factors for deep surgical site infection after posterior cervical spine surgery in adults: a multicentre observational cohort study.Scientific reports · 2021Observational
- C-spine clearance in poly-trauma patients: A narrative review.Journal of clinical orthopaedics and trauma · 2021Article
- Cervical spine clearance after blunt trauma: current state of the art.EFORT open reviews · 2020Review
- Effectiveness of orthoses for treatment in patients with spinal pain.Yeungnam University journal of medicine · 2020Article
- Cervical collars and immobilisation: A South African best practice recommendation.African journal of emergency medicine : Revue africaine de la medecine d'urgence · 2017Article
- Management of maxillofacial trauma in emergency: An update of challenges and controversies.Journal of emergencies, trauma, and shockReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cervical immobilisation is commonly applied following trauma, particularly blunt head injury, but current methods of immobilisation are associated with significant complications. Semi-rigid disposable cervical collars are known to cause pressure ulcers, and impede effective airway management. These collars may also exacerbate a head injury by increasing intracranial pressure as a result of external compression of the jugular veins. There is a clear imperative to find ways of effectively immobilising the cervical spine whilst minimising complications, and any assessment of existing or new devices should include a standardized approach to the measurement of tissue interface pressures and their effect on jugular venous drainage from the brain. This systematic review summarises the research methods and technologies that have been used to measure tissue interface pressure and assess the jugular vein in the context of cervical immobilisation devices. 27 papers were included and assessed for quality. Laboratory investigations and biomechanical studies have gradually given way to methods that more accurately reflect clinical care. There are numerous accounts of skin ulceration associated with cervical collars, but no standardised approach to measuring tissue interface pressure. It is therefore difficult to compare studies and devices, but a pressure of less than 30 mmHg appears desirable. Cervical collars have been shown to have a compressive effect on the jugular veins, but it is not yet certain that this is the cause of the increased intracranial pressure observed in association with cervical collar use. This is the first review of its type. It will help guide further research in this area of trauma care, and the development and testing of new cervical immobilisation devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials