Evidence map›Paper›PMID 24292495›Full record

ArticleJournal of biomechanical engineering2014

Finite element prediction of transchondral stress and strain in the human hip.

Corinne R Henak, Gerard A Ateshian, Jeffrey A Weiss

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanical engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.6field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Development and experimental validation of a dynamic numerical model for human articular cartilage.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Corinne R Henak
Gerard A Ateshian
Jeffrey A Weiss
University of Utah · USColumbia University · US

Funding

Finite Elements For Biomechanics And BiophysicsR01GM083925 · NIGMS · UTAH STATE HIGHER EDUCATION SYSTEM--UNIVERSITY OF UTAH · PI GERARD A. ATESHIAN, JEFFREY A. WEISS · 2008 to 2026
$7.6M
Biomechanics of the Dysplastic HipR01AR053344 · NIAMS · UNIVERSITY OF UTAH · PI WEISS, JEFFREY A. · 2007 to 2011
$1.3M
NIAMS NIH HHS R01 AR053344NIAMS NIH HHS R01AR053344NIGMS NIH HHS R01 GM083925NIGMS NIH HHS R01GM083925
6 · The paper itself

Abstract

Cartilage fissures, surface fibrillation, and delamination represent early signs of hip osteoarthritis (OA). This damage may be caused by elevated first principal (most tensile) strain and maximum shear stress. The objectives of this study were to use a population of validated finite element (FE) models of normal human hips to evaluate the required mesh for converged predictions of cartilage tensile strain and shear stress, to assess the sensitivity to cartilage constitutive assumptions, and to determine the patterns of transchondral stress and strain that occur during activities of daily living. Five specimen-specific FE models were evaluated using three constitutive models for articular cartilage: quasilinear neo-Hookean, nonlinear Veronda Westmann, and tension-compression nonlinear ellipsoidal fiber distribution (EFD). Transchondral predictions of maximum shear stress and first principal strain were determined. Mesh convergence analysis demonstrated that five trilinear elements were adequate through the depth of the cartilage for precise predictions. The EFD model had the stiffest response with increasing strains, predicting the largest peak stresses and smallest peak strains. Conversely, the neo-Hookean model predicted the smallest peak stresses and largest peak strains. Models with neo-Hookean cartilage predicted smaller transchondral gradients of maximum shear stress than those with Veronda Westmann and EFD models. For FE models with EFD cartilage, the anterolateral region of the acetabulum had larger peak maximum shear stress and first principal strain than all other anatomical regions, consistent with observations of cartilage damage in disease. Results demonstrate that tension-compression nonlinearity of a continuous fiber distribution exhibiting strain induced anisotropy incorporates important features that have large effects on predictions of transchondral stress and strain. This population of normal hips provides baseline data for future comparisons to pathomorphologic hips. This approach can be used to evaluate these and other mechanical variables in the human hip and their potential role in the pathogenesis of osteoarthritis (OA).

Indexed as

Models, BiologicalCartilage, ArticularCompressive StrengthComputer SimulationElastic ModulusFinite Element AnalysisHip JointHumansShear StrengthStress, MechanicalTensile Strength

Identifiers

PMID24292495
PMCPMC5101027
OpenAlexW2059262248

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.