Evidence map›Paper›PMID 24272224›Full record

Trial reportEuropean radiology2014

Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols.

Makiko Fujita, Kakuya Kitagawa, Tatsuro Ito, Yasuyuki Shiraishi, Yusuke Kurobe, Motonori Nagata, Masaki Ishida, Hajime Sakuma

Registry-linked trialAbstract readComparative StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in European radiology, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03324308 (The Safety, Feasibility and Accuracy of Dynamic Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease), which is not on this map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
3.2field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03324308 nawithdrawnnot on this mapstarted 2018, after this paper: background citation

The Safety, Feasibility and Accuracy of Dynamic Computed Tomography Myocardial Perfusion Imaging for Detection of Coronary Artery Disease

TypeinterventionalSponsorJohns Hopkins UniversityRan2018 to 2022Enrolled0ConditionsCoronary Artery Disease, IschemiaArmsComputed Tomography Angiography
3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 47 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Cardiac CT perfusion and FFRCardiovascular diagnosis and therapy · 2020
    Review
  11. Article
  12. Article
  13. Imaging of coronary flow capacity: is there a role for dynamic CT perfusion imaging?European journal of nuclear medicine and molecular imaging · 2019
    Article
  14. Article
  15. Review
  16. Review
  17. Article
  18. Static and dynamic assessment of myocardial perfusion by computed tomography.European heart journal. Cardiovascular Imaging · 2016
    Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Makiko FujitaDepartment of Radiology, Mie University School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan.
Kakuya Kitagawa
Tatsuro Ito
Yasuyuki Shiraishi
Yusuke Kurobe
Motonori Nagata
Masaki Ishida
Hajime Sakuma
Mie University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo determine the effect of reduced 80-kV tube voltage with increased 370-mAs tube current on radiation dose, image quality and estimated myocardial blood flow (MBF) of dynamic CT stress myocardial perfusion imaging (CTP) in patients with a normal body mass index (BMI) compared with a 100-kV and 300-mAs protocol.

methodsThirty patients with a normal BMI (<25 kg/m(2)) with known or suspected coronary artery disease underwent adenosine-stress dual-source dynamic CTP. Patients were randomised to 80-kV/370-mAs (n = 15) or 100-kV/300-mAs (n = 15) imaging. Maximal enhancement and noise of the left ventricular (LV) cavity, contrast-to-noise ratio (CNR) and MBF of the two groups were compared.

resultsImaging with 80-kV/370-mAs instead of 100-kV/300-mAs was associated with 40% lower radiation dose (mean dose-length product, 359 ± 66 vs 628 ± 112 mGy[Symbol: see text]cm; P < 0.001 ) with no significant difference in CNR (34.5 ± 13.4 vs 33.5 ± 10.4; P = 0.81) or MBF in non-ischaemic myocardium (0.95 ± 0.20 vs 0.99 ± 0.25 ml/min/g; P = 0.66). Studies obtained using 80-kV/370-mAs were associated with 30.9% higher maximal enhancement (804 ± 204 vs 614 ± 115 HU; P < 0.005), and 31.2% greater noise (22.7 ± 3.5 vs 17.4 ± 2.6; P < 0.001).

conclusionsDynamic CTP using 80-kV/370-mA instead of 100-kV/300-mAs allowed 40% dose reduction without compromising image quality or MBF. Tube voltage of 80-kV should be considered for individuals with a normal BMI. KEY POINTS: • CT stress perfusion imaging (CTP) is increasingly used to assess myocardial function. • Dynamic CTP is feasible at 80-kV in patients with normal BMI. • An 80-kV/370-mAs protocol allows 40% dose reduction compared with 100-kV/300-mAs. • Contrast-to-noise ratio and myocardial blood flow of the two protocols were comparable.

Indexed as

AdenosineAgedArtifactsBody Mass IndexCoronary AngiographyCoronary Artery DiseaseCoronary CirculationExercise TestFemaleHumansMaleMiddle AgedMyocardial Perfusion ImagingRadiation DosageTomography, X-Ray ComputedVasodilator AgentsAdenosineVasodilator Agents

Identifiers

PMID24272224
OpenAlexW2053595822

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials