Evidence map›Paper›PMID 24266297›Full record

ReviewBiochemia medica2013

Exhaled breath condensate--from an analytical point of view.

Slavica Dodig, Ivana Cepelak

Abstract readReview
In one paragraph

Review in Biochemia medica, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Observational
  8. Noninvasive glucose detection in exhaled breath condensate.Translational research : the journal of laboratory and clinical medicine · 2019
    Review
  9. Observational
  10. Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Slavica DodigDepartment of Clinical Laboratory Diagnosis, Srebrnjak Children's Hospital, Zagreb, Croatia. slavica.dodig@zg.t-com.hr
Ivana Cepelak

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease.

Indexed as

Breath TestsBiomarkersExhalationHumansHumiditySpecimen HandlingTemperatureBiomarkers