Evidence map›Paper›PMID 24257278›Full record

ArticleJournal of applied clinical medical physics2013

Using patient-specific phantoms to evaluate deformable image registration algorithms for adaptive radiation therapy.

Nick Stanley, Carri Glide-Hurst, Jinkoo Kim, Jeffrey Adams, Shunshan Li, Ning Wen, Indrin J Chetty, Hualiang Zhong

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Development of a Computerized 4-D MRI Phantom for Liver Motion Study.Technology in cancer research & treatment · 2017
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Methodology for Registration of Shrinkage Tumors in Head-and-Neck CT Studies.Computational and mathematical methods in medicine · 2015
    Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nick StanleyHenry Ford Health System. Nick.Stanley@mclaren.org.
Carri Glide-Hurst
Jinkoo Kim
Jeffrey Adams
Shunshan Li
Ning Wen
Indrin J Chetty
Hualiang Zhong

Funding

To quantify deformable image registration errors in IGRTR01CA140341 · NCI · HENRY FORD HEALTH SYSTEM · PI ZHONG, HUALIANG · 2010 to 2014
$1.5M
NCI NIH HHS R01 CA140341NCI NIH HHS R01CA140341
6 · The paper itself

Abstract

The quality of adaptive treatment planning depends on the accuracy of its underlying deformable image registration (DIR). The purpose of this study is to evaluate the performance of two DIR algorithms, B-spline-based deformable multipass (DMP) and deformable demons (Demons), implemented in a commercial software package. Evaluations were conducted using both computational and physical deformable phantoms. Based on a finite element method (FEM), a total of 11 computational models were developed from a set of CT images acquired from four lung and one prostate cancer patients. FEM generated displacement vector fields (DVF) were used to construct the lung and prostate image phantoms. Based on a fast-Fourier transform technique, image noise power spectrum was incorporated into the prostate image phantoms to create simulated CBCT images. The FEM-DVF served as a gold standard for verification of the two registration algorithms performed on these phantoms. The registration algorithms were also evaluated at the homologous points quantified in the CT images of a physical lung phantom. The results indicated that the mean errors of the DMP algorithm were in the range of 1.0 ~ 3.1 mm for the computational phantoms and 1.9 mm for the physical lung phantom. For the computational prostate phantoms, the corresponding mean error was 1.0-1.9 mm in the prostate, 1.9-2.4mm in the rectum, and 1.8-2.1 mm over the entire patient body. Sinusoidal errors induced by B-spline interpolations were observed in all the displacement profiles of the DMP registrations. Regions of large displacements were observed to have more registration errors. Patient-specific FEM models have been developed to evaluate the DIR algorithms implemented in the commercial software package. It has been found that the accuracy of these algorithms is patient dependent and related to various factors including tissue deformation magnitudes and image intensity gradients across the regions of interest. This may suggest that DIR algorithms need to be verified for each registration instance when implementing adaptive radiation therapy.

Indexed as

AlgorithmsCone-Beam Computed TomographyRadiographic Image Interpretation, Computer-AssistedComputer SimulationHumansImage Processing, Computer-AssistedLung NeoplasmsMaleProstateRadiotherapy DosageRetrospective Studies

Identifiers

PMID24257278
PMCPMC4041490

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.