Evidence map›Paper›PMID 24253956›Full record

Trial reportEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2014

Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study.

Ben Ockert, Vera Pedersen, Lucas Geyer, Stefan Wirth, Wolf Mutschler, Stefan Grote

Abstract readComparative StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Interventions for treating proximal humeral fractures in adults.The Cochrane database of systematic reviews · 2022
    Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Grafting and fixation of proximal humeral aseptic non union: a prospective case series.Clinical cases in mineral and bone metabolism : the official journal of the Italian Society of Osteoporosis, Mineral Metabolism, and Skeletal Diseases
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ben OckertDepartment of Trauma and Orthopaedic Surgery, Ludwig-Maximilians-University, Nussbaumstr. 20, 80336, Munich, Germany, ben.ockert@med.uni-muenchen.de.
Vera Pedersen
Lucas Geyer
Stefan Wirth
Wolf Mutschler
Stefan Grote

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAim of the study was to compare the chosen position of polyaxial locking screws with the position of monoaxial screws in the humeral head of proximal humeral fractures treated by locked plating.

methodsIn a prospective randomized observational study, 124 consecutive patients (mean age 70.9±14.8 years) sustaining a displaced proximal humeral fracture were treated with either monoaxial or polyaxial screw-inserted locking plate fixation. The chosen positions of locking screws were identified from standardized postoperative radiographs in anteroposterior and outlet-view, with regard to a regional mapping of the humeral head.

resultsIn monoaxial locking technique, a mean of 6 screws purchased the humeral head (95% CI 5.1-6.2), and in polyaxial locking technique, a mean of 4 screws (95% CI 3.3-4.5), respectively. Screws were placed in the regions superolateral: monoaxial 24.8%, polyaxial 20.7% (p=0.49); superomedial: monoaxial 21.9%, polyaxial 20.0% (p=0.433); inferolateral: monoaxial 32.5%, polyaxial 35.0% (p=0.354); inferomedial: monoaxial 20.8%, polyaxial 24.2% (p=0.07), superoposterior: monoaxial 45.5%, polyaxial 30.8% (p=0.57); superoanterior: monoaxial 4.4%, polyaxial 8.3% (p=0.33); inferoposterior: monoaxial 22.5%, polyaxial 29.8% (p=0.49) and inferoanterior: monoaxial 27.5%, polyaxial: 31.2% (p=0.09).

conclusionThe chosen screws' position in monoaxial and polyaxial locking plate fixation of displaced proximal humeral fractures do not differ significantly. However, loss of fixation is observed more frequently if the fixation did not include at least one screw within the superoposterior region of the humeral head, suggesting that a screw purchasing the superoposterior region is beneficial in locked plating of proximal humeral fractures. LEVEL OF EVIDENCE: Treatment Study, Level II.

Indexed as

Bone PlatesBone ScrewsFracture Fixation, InternalShoulder FracturesAgedAnalysis of VarianceFemaleHumansMalePostoperative ComplicationsProspective StudiesProsthesis FailureRadiographyReoperation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.