Evidence map›Paper›PMID 24244335›Full record

SynthesisPloS one2013

Efficacy and safety of biodegradable polymer biolimus-eluting stents versus durable polymer drug-eluting stents: a meta-analysis.

Yicong Ye, Hongzhi Xie, Yong Zeng, Xiliang Zhao, Zhuang Tian, Shuyang Zhang

Open access · goldAbstract readMeta-AnalysisReview
In one paragraph

Synthesis in PloS one, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 3 pooled it
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 3 syntheses or guidelines pooled it, 13 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Trial
  5. Comparison of long-term clinical outcomes of bioabsorbable polymer versus durable polymer drug-eluting stents: a systematic review and meta-analysis.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2024
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yicong YeDepartment of Cardiology, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing, China.
Hongzhi Xie
Yong Zeng
Xiliang Zhao
Zhuang Tian
Shuyang Zhang
Chinese Academy of Medical Sciences & Peking Union Medical College · CNPeking Union Medical College Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundsDrug-eluting stents (DES) with biodegradable polymers have been developed to address the risk of thrombosis associated with first-generation DES. We aimed to determine the efficacy and safety of biodegradable polymer biolimus-eluting stents (BES) versus durable polymer DES.

methodsSystematic database searches of MEDLINE (1950 to June 2013), EMBASE (1966 to June 2013), the Cochrane Central Register of Controlled Trials (Issue 6 of 12, June 2013), and a review of related literature were conducted. All randomized controlled trials comparing biodegradable polymer BES versus durable polymer DES were included.

resultsEight randomized controlled trials investigating 11,015 patients undergoing percutaneous coronary interventions were included in the meta-analysis. The risk of major adverse cardiac events did not differ significantly between the patients treated with the biodegradable polymer BES and the durable polymer DES (Relative risk [RR], 0.970; 95% CI, 0.848-1.111; p = 0.662). However, biodegradable polymer BES was associated with reduced risk of very late ST compared with the durable polymer DES, while the risk of early or late ST was similar (RR for early or late ST, 1.167; 95% CI 0.755-1.802; p = 0.487; RR 0.273; 95% CI 0.115-0.652; p = 0.003; p for interaction = 0.003).

conclusionsIn this meta-analysis of randomized controlled trials, treatments with biodegradable polymer BES did not significantly reduce the risk of major adverse cardiac events, but demonstrated a significantly lower risk of very late ST when compared to durable polymer DES. This conclusion requires confirmation by further studies with long-term follow-up. PROSPERO REGISTER NUMBER: http://www.crd.york.ac.uk/PROSPERO/display_record.asp?ID=CRD42013004364#.UnM2lfmsj6J.

Indexed as

Biodegradable PlasticsImmunosuppressive AgentsSirolimusDrug-Eluting StentsFemaleHumansMaleMEDLINERandomized Controlled Trials as TopicRisk FactorsBiodegradable PlasticsImmunosuppressive AgentsSirolimus

Identifiers

PMID24244335
PMCPMC3823917
OpenAlexW1998767105

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.