ArticleAnalytical chemistry2013
Oil-isolated hydrogel microstructures for sensitive bioassays on-chip.
Article in Analytical chemistry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 24 citations in OpenAlex.
- Oil-sealed RGD-modified alginate hydrogel microwell array for analysis of single-cell-derived extracellular vesicles and particles.Microsystems & nanoengineering · 2025Article
- Hydrogel-Based Colorimetric Assay for Multiplexed MicroRNA Detection in a Microfluidic Device.Analytical chemistry · 2020Article
- Light-inducible activation of cell cycle progression in Xenopus egg extracts under microfluidic confinement.Lab on a chip · 2019Article
- Recent Advances in Design of Fluorescence-Based Assays for High-Throughput Screening.Analytical chemistry · 2019Review
- Fabrication of Functional Biomaterial Microstructures by in Situ Photopolymerization and Photodegradation.ACS biomaterials science & engineering · 2018Article
- Microparticle parking and isolation for highly sensitive microRNA detection.Lab on a chip · 2017Article
- Cytocompatible cell encapsulation via hydrogel photopolymerization in microfluidic emulsion droplets.Biomicrofluidics · 2017Article
- Bioengineering Microgels and Hydrogel Microparticles for Sensing Biomolecular Targets.Gels (Basel, Switzerland) · 2017Review
- National Institute of Biomedical Imaging and Bioengineering Point-of-Care Technology Research Network: Advancing Precision Medicine.IEEE journal of translational engineering in health and medicine · 2016Article
- Fiber composite slices for multiplexed immunoassays.Biomicrofluidics · 2015Article
- Sensitive and multiplexed on-chip microRNA profiling in oil-isolated hydrogel chambers.Angewandte Chemie (International ed. in English) · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Multiplexed, sensitive, and on-chip molecular diagnostic assays are essential in both clinical and research settings. In past work, running reactions in nanoliter- to femtoliter-sized volumes such as microwells or droplets has led to significant increases in detection sensitivities. At the same time, hydrogels have emerged as attractive scaffolds for bioassays due to their nonfouling, flexible, and aqueous properties. In this paper, we combine these concepts and develop a novel platform in which hydrogel compartments are used as individually confined reaction volumes within a fluorinated oil phase. We fabricate functional and versatile hydrogel microstructures in microfluidic channels that are physically isolated from each other using a surfactant-free fluorinated oil phase, generating picoliter- to nanoliter-sized immobilized aqueous reaction compartments that are readily functionalized with biomolecules. In doing so, we achieve monodisperse reaction volumes with an aqueous interior while exploiting the unique chemistry of a hydrogel, which provides a solid and porous binding scaffold for biomolecules and is impenetrable to oil. Furthermore, our lithographically defined reaction volumes are readily customized with respect to geometry and chemistry within the same channel, allowing rational tuning of the confined reaction volume on a post-to-post basis without needing to use surfactants to maintain stability. We design and implement a multiplexed signal amplification assay in which gel-bound enzymes turn over small molecule substrate into fluorescent product in the oil-confined gel compartment, providing significant signal enhancement. Using short (20 min) amplification times, the encapsulation scheme provides up to 2 orders of magnitude boost of signal in nucleic acid detection assays relative to direct labeling and does not suffer from any cross-talk between the posts. We ultimately demonstrate up to 57-fold increase in nucleic acid detection sensitivity compared to a direct labeling scheme.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials