ArticleBMC musculoskeletal disorders2013
Is the use of computer navigation in total knee arthroplasty improving implant positioning and function? A comparative study of 198 knees operated at a Norwegian district hospital.
Article in BMC musculoskeletal disorders, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.
- Use of intraoperative technology in total knee arthroplasty is not associated with reductions in postoperative pain.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Pooled it
- Radiostereometric measurement of implant migration in robotically assisted vs conventional bi-cruciate stabilized cemented total knee arthroplasty: secondary analysis of a randomized controlled trial.Acta orthopaedica · 2025Trial
- Similar migration in computer-assisted and conventional total knee arthroplasty.Acta orthopaedica · 2017Trial
- Article
- The effect of posterior tibial slope on anteroposterior stability in posterior cruciate retaining total knee arthroplasty.BMC musculoskeletal disorders · 2023Article
- Comparative Study of Pinless Navigation System versus Conventional Instrumentation in Total Knee Arthroplasty.Clinics in orthopedic surgery · 2021Observational
- Patient-specific and intra-operatively modifiable factors assessed by computer navigation predict maximal knee flexion one year after TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2016Article
- A Systematic Literature Review of Three Modalities in Technologically Assisted TKA.Advances in orthopedics · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThere are few Scandinavian studies on the effect of computer assisted orthopedic surgery (CAOS) in total knee arthroplasty (TKA), compared to conventional technique (CON), and there is little information on effects in pain and function scores. This retrospective study has evaluated the effects of CAOS on radiological parameters and pain, function and quality of life after primary TKA.
methods198 primary TKAs were operated by one surgeon in two district hospitals; 103 CAOS and 95 CON. The groups were evaluated based on 3 months post-operative radiographs and a questionnaire containing the knee osteoarthritis outcome score (KOOS), the EQ-5D index score and a visual analogue scale (VAS) two years after surgery. Multiple linear regression method was used to investigate possible impact from exposure (CON or CAOS).
resultsOn hip-knee-ankle radiographs, 20% of measurements were > ±3° of neutral in the CAOS group and 25% in the CON group (p = 0.37). For the femoral component, the number was 5% for CAOS and 18% for CON (p < 0.01). For the tibial component, the difference was not statistically significant (p = 0.58). In the sagittal plane, the surgeon tended to apply more femoral flexion and more posterior tibial slope with CAOS. We observed no statistically or clinically significant difference in KOOS score, VAS or ∆EQ-5D (all p values >0.05), but there was a trend towards better scores for CAOS. Operation time was 3 minutes longer for CON (p = 0.37).
conclusionsCAOS can improve radiological measurements in primary TKA, and makes it possible to adjust component placement to the patient's anatomy. Over-all, the two methods are equal in pain, function and quality-of-life scores.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.