Evidence map›Paper›PMID 24206675›Full record

ArticleUltrasonics2014

Multi-frequency axial transmission bone ultrasonometer.

Alexey Tatarinov, Vladimir Egorov, Noune Sarvazyan, Armen Sarvazyan

Open access · greenAbstract read
In one paragraph

Article in Ultrasonics, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
4.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 37 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Signal Processing Techniques Applied to Axial Transmission Ultrasound.Advances in experimental medicine and biology · 2022
    Article
  4. Clinical Devices for Bone Assessment.Advances in experimental medicine and biology · 2022
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Ultrasound to assess bone quality.Current osteoporosis reports · 2014
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Alexey TatarinovArtann Laboratories, Trenton, NJ 08618, USA. Electronic address: alta2003@apollo.lv.
Vladimir EgorovArtann Laboratories, Trenton, NJ 08618, USA.
Noune SarvazyanArtann Laboratories, Trenton, NJ 08618, USA.
Armen SarvazyanArtann Laboratories, Trenton, NJ 08618, USA.
Artann Laboratories, Inc. · US

Funding

PORTABLE ULTRASONOMETER for OSTEOPOROSIS ASSESSMENTR44AG017400 · NIA · ARTANN LABORATORIES, INC. · PI SARVAZYAN, ARMEN · 2001 to 2010
$2.5M
NIA NIH HHS R44 AG017400NIA NIH HHS R44AG017400
6 · The paper itself

Abstract

The last decade has seen a surge in the development of axial transmission QUS (Quantitative UltraSound) technologies for the assessment of long bones using various modes of acoustic waves. The condition of cortical bones and the development of osteoporosis are determined by numerous mechanical, micro-structural, and geometrical or macro-structural bone properties like hardness, porosity and cortical thickness. Such complex manifestations of osteoporosis require the evaluation of multiple parameters with different sensitivities to the various properties of bone that are affected by the disease. This objective may be achieved by using a multi-frequency ultrasonic examination The ratio of the acoustic wavelength to the cortical thickness can be changed by varying the frequency of the ultrasonic pulse propagating through the long bone that results in the change in composition of the induced wave comprised of a set of numerous modes of guided, longitudinal, and surface acoustic waves. The multi-frequency axial transmission QUS method developed at Artann Laboratories (Trenton, NJ) is implemented in the Bone Ultrasonic Scanner (BUSS). In the current version of the BUSS, a train of ultrasonic pulses with 60, 100, 400, 800, and 1200 kHz frequencies is used. The developed technology was tested on a variety of bone phantoms simulating normal, osteopenic, and osteoporotic bones. The results of this study confirm the feasibility of the multi-frequency approach for the assessment of the processes leading to osteoporosis.

Indexed as

Bone and BonesEquipment DesignErgonomicsFeasibility StudiesHumansOsteoporosisPhantoms, ImagingPorositySignal TransductionUltrasonographyBone quantitative ultrasoundMulti-frequency axial transmission scannerOsteoporosis

Identifiers

PMID24206675
PMCPMC4205948
OpenAlexW2069727291

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.