Evidence map›Paper›PMID 24191173›Full record

ArticleEvidence-based complementary and alternative medicine : eCAM2013

New assessment model of pulse depth based on sensor displacement in pulse diagnostic devices.

Jang-Han Bae, Young Ju Jeon, Jong Yeol Kim, Jaeuk U Kim

Open access · hybridAbstract read
In one paragraph

Article in Evidence-based complementary and alternative medicine : eCAM, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 41 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Peripheral pulse harmonic analysis and its clinical application: A systematic review.Journal of traditional and complementary medicine · 2024
    Article
  6. Article
  7. Article
  8. A Noncontact Method for Locating Radial Artery above Radial Styloid Process in Thermal Image.Evidence-based complementary and alternative medicine : eCAM · 2020
    Article
  9. Article
  10. Article
  11. Article
  12. Anatomy of the Cun Position at Wrist and Its Application in Pulse Diagnosis.Evidence-based complementary and alternative medicine : eCAM · 2019
    Article
  13. Article
  14. Observational
  15. Development of a Cardiovascular Simulator for Studying Pulse Diagnosis Mechanisms.Evidence-based complementary and alternative medicine : eCAM · 2017
    Article
  16. Study on the Depth, Rate, Shape, and Strength of Pulse with Cardiovascular Simulator.Evidence-based complementary and alternative medicine : eCAM · 2017
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Jang-Han BaeBiomedical Engineering Research Division, Korea Institute of Oriental Medicine, Daejeon 305-811, Republic of Korea.
Young Ju Jeon
Jong Yeol Kim
Jaeuk U Kim
Korea Institute of Oriental Medicine · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An accurate assessment of the pulse depth in pulse diagnosis is vital to determine the floating and sunken pulse qualities (PQs), which are two of the four most basic PQs. In this work, we proposed a novel model of assessing the pulse depth based on sensor displacement (SD) normal to the skin surface and compared this model with two previous models which assessed the pulse depth using contact pressure (CP). In contrast to conventional stepwise CP variation tonometry, we applied a continuously evolving tonometric mechanism at a constant velocity and defined the pulse depth index as the optimal SD where the largest pulse amplitude was observed. By calculating the pulse depth index for 18 volunteers, we showed that the pulse was deepest at Cheok (significance level: P < 0.01), while no significant difference was found between Chon and Gwan. In contrast, the two CP-based models estimated that the pulse was shallowest at Gwan (P < 0.05). For the repeated measures, the new SD-based model showed a smaller coefficient of variation (CV ≈ 7.6%) than the two CP-based models (CV ≈ 13.5% and 12.3%, resp.). The SD-based pulse depth assessment is not sensitive to the complex geometry around the palpation locations and temperature variation of contact sensors, which allows cost-effective sensor technology.

Identifiers

PMID24191173
PMCPMC3804036
OpenAlexW2159555938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.