Evidence map›Paper›PMID 24188417›Full record

ArticleBMC clinical pathology2013

A mill based instrument and software system for dissecting slide-mounted tissue that provides digital guidance and documentation.

Nils Adey, Dale Emery, Derek Bosh, Steven Callahan, John Schreiner, Yang Chen, Ann Greig, Katherine Geiersbach, Robert Parry

Abstract read
In one paragraph

Article in BMC clinical pathology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. 3D pathology-guided microdissection.bioRxiv : the preprint server for biology · 2025
    Article
  4. Article
  5. Artificial intelligence-augmented histopathologic review using image analysis to optimize DNA yield from formalin-fixed paraffin-embedded slides.Modern pathology : an official journal of the United States and Canadian Academy of Pathology, Inc · 2022
    Article
  6. Article
  7. Article
  8. Microdissection approaches in tuberculosis research.Journal of medical primatology · 2014
    Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Nils AdeyAvanSci Bio, LLC, 1290 West 2320 South, Suite D, Salt Lake City, UT 84119-1476, USA. nils@avanscibio.com.
Dale Emery
Derek Bosh
Steven Callahan
John Schreiner
Yang Chen
Ann Greig
Katherine Geiersbach
Robert Parry

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDissection of specific Areas Of Interest (AOIs) of slide-mounted tumor samples is often used to enrich for cancer cells in order to generate better signal to noise ratios in subsequent biochemical characterization. Most clinical laboratories utilize manual dissection for practical reasons and to avoid the expense and difficulties of laser microdissection systems. Unfortunately, manual methods often lack resolution and process documentation. The goal of this project was to design a dissection system for slide-mounted tissue with better precision than manual methods that also provides digital image guidance and electronic process documentation.

methodsAn instrument that is essentially a micro tissue mill was developed. It employs a specialized disposable mill bit that simultaneously dispenses liquid, cuts tissue from the slide surface, and aspirates the liquid along with the displaced tissue fragments. A software package was also developed that is capable of transferring digitally annotated AOIs between images of serially cut tissue sections to guide dissection and generate an electronic record of the process.

resultsThe performance of this "meso" dissection system was tested using post dissection visual examination for resolution and accuracy, fluorescence based DNA quantitation for recovery efficiency, and dissection of closely situated mouse-human tissue sections followed by PCR amplification for purity determination. The minimum resolution is a dissected circle smaller than 200 microns in diameter, edge dissection accuracy is tighter than 100 microns, recovery efficiency appears greater than 95%, and recovery purity is greater than 99% relative to a different tissue located 100 microns from the dissection boundary. The system can dissect from both paraffinized and deparaffinized FFPE tissue sections that are mounted on plain glass slides, and it is compatible with DNA, RNA, and protein isolation.

conclusionsThe mesodissection system is an effective alternative to manual dissection methods and is applicable for biomarker analysis of anatomical pathology samples, where enrichment of AOIs from the tissue section is helpful, but pure cell populations are not required.

Identifiers

PMID24188417
PMCPMC3826833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.