ArticleJournal of clinical and diagnostic research : JCDR2013
Influence of delivery devices on efficacy of inhaled fluticasone propionate: a comparative study in stable asthma patients.
Article in Journal of clinical and diagnostic research : JCDR, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- A cross-sectional study of the availability and pharmacist's knowledge of nano-pharmaceutical drugs in Palestinian hospitals.BMC health services research · 2018Article
- Comparison of fluticasone propionate with budesonide administered via nebulizer: a randomized controlled trial in patients with severe persistent asthma.Journal of thoracic disease · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInhaled corticosteroids are the preferred treatment for long-term control of all grades of persistent asthma. These are administered by various delivery devices with very little information whether these devices can affect the efficacy of inhaled corticosteroids. Fluticasone propionate is a relatively new inhalational corticosteroid compared to older ones like beclomethasone and budesonide. Aims & Objective: To assess the relative efficacy of fluticasone propionate administered from different delivery devices to adult patients of chronic stable bronchial asthma as measured by pulmonary function test parameters. MATERIAL AND
methodsThis prospective study was undertaken to assess the relative efficacy of fluticasone propionate administered from different delivery devices to adult patients of chronic stable bronchial asthma as measured by pulmonary function test parameters. Fourty eight subjects were administered, fluticasone propionate (250 μg) by dry powder inhaler, metered dose inhaler, metered dose inhaler with spacer and fluticasone (1mg) via nebulizer consecutively each week for four weeks under direct supervision. Pulmonary function test was done before and one hour after administration of the drug on each visit.
resultsAfter excluding nine patients who were lost to follow up, data was analysed for the remaining thirty nine patients and no significant difference in peak expiratory flow rate (p=0.77), forced expiratory volume in one second (p=0.95), forced vital capacity (p=0.24) and forced expiratory volume in one second and forced vital capacity ratio (p=0.22) was seen after giving fluticasone by different devices.
conclusionFluticasone propionate delivered by different devices like dry powder inhaler, metered dose inhaler, metered dose inhaler with spacer and nebulizer have similar effect on lung function in patients of chronic stable bronchial asthma and may be used interchangeably.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.