Evidence map›Paper›PMID 24167637›Full record

Trial reportPloS one2013

The PhysioFlow thoracic impedancemeter is not valid for the measurements of cardiac hemodynamic parameters in chronic anemic patients.

Pascal Bogui, Edwige Balayssac-Siransy, Philippe Connes, Nalourgo Tuo, Soualiho Ouattara, Aurélien Pichon, Cyrille Serges Dah

Abstract readClinical Trial
In one paragraph

Trial report in PloS one, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Understanding the Haemodynamics of Hypertension.Current hypertension reports · 2018
    Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Pascal BoguiLaboratoire de Physiologie et d'Explorations Fonctionnelles, Unité de Formation et de Recherche en Sciences Médicales, Université Félix Houphouët Boigny, Abidjan, Côte d'Ivoire ; Service des explorations fonctionnelles et endoscopiques, Centre hospitalier universitaire de Yopougon, Abidjan, Côte d'Ivoire.
Edwige Balayssac-Siransy
Philippe Connes
Nalourgo Tuo
Soualiho Ouattara
Aurélien Pichon
Cyrille Serges Dah

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of the present study was to test the validity of the transthoracic electrical bioimpedance method PhysioFlow® to measure stroke volume in patients with chronic anemia. Stroke volume index (SVI), as well as cardiac index (CI) obtained by transthoracic electrical bioimpedance method and doppler echocardiography were compared in healthy subjects (n = 25) and patients with chronic anemia (i.e. mainly with sickle cell anemia; n = 32), at rest. While doppler echocardiography was able to detect difference in SVI between the two populations, the Physioflow® failed to detect any difference. Bland & Altman analyses have demonstrated no interchangeability between the two methods to assess CI and SVI in anemic patients and healthy subjects. While doppler echocardiography displayed a good concordance for SVI results with those obtained in the literature for anemic patients, the Physioflow® did not. Finally, in contrast to doppler echocardiography: 1) the CI obtained with the Physioflow® was not correlated with the hemoglobin level and 2) the stroke volume determined by the Physioflow® was highly influenced by body surface area. In conclusion, our findings indicate that the Physioflow® device is inaccurate for the measurement of SVI and CI in patients with chronic anemia and has a poor accuracy for the measurement of these parameters in African healthy subjects.

Indexed as

Stroke VolumeAdultAnemiaChronic DiseaseCote d'IvoireEchocardiography, DopplerElectric ImpedanceFemaleHumansMale

Identifiers

PMID24167637
PMCPMC3805528

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.