SynthesisThe Cochrane database of systematic reviews2013
Reading aids for adults with low vision.
Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed, 4 syntheses or guidelines pooled it, 54 citations in OpenAlex.
- Reading aids for adults with low vision.The Cochrane database of systematic reviews · 2018Pooled it
- The treatment methods for post-stroke visual impairment: A systematic review.Brain and behavior · 2017Pooled it
- Assistive technology for children and young people with low vision.The Cochrane database of systematic reviews · 2015Pooled it
- Optical reading aids for children and young people with low vision.The Cochrane database of systematic reviews · 2015Pooled it
- Visual rehabilitation of patients with corneal diseases.BMC ophthalmology · 2020Trial
- Adding access to a video magnifier to standard vision rehabilitation: initial results on reading performance and well-being from a prospective, randomized study.Digital journal of ophthalmology : DJO · 2017Trial
- The impact of simulated visual impairment on medication use process: A study with healthy volunteers.Exploratory research in clinical and social pharmacy · 2025Article
- Food insecurity and associated health and social determinants among older adults in Ghana: Analysis of the WHO's study on global AGEing and adult health (SAGE), 2014-2015.Preventive medicine reports · 2024Article
- The Effects of a Novel Treatment for Hemianopic Dyslexia on Reading, Symptom Load, and Return to Work.Brain sciences · 2024Article
- Article
- Clinical performance of a smartphone-based low vision aid.Scientific reports · 2022Article
- Article
- Visual impairment and social isolation, depression and life satisfaction among older adults in Ghana: analysis of the WHO's Study on global AGEing and adult health (SAGE) Wave 2.BMJ open ophthalmology · 2020Article
- A Primary Care Provider's Guide to Cataract Surgery in the Very Elderly.Federal practitioner : for the health care professionals of the VA, DoD, and PHS · 2019Article
- Scotoma Simulation in Healthy Subjects.Optometry and vision science : official publication of the American Academy of Optometry · 2018Article
- Korean reading speed: Effects of print size and retinal eccentricity.Vision research · 2018Article
- The Effect of a Head-mounted Low Vision Device on Visual Function.Optometry and vision science : official publication of the American Academy of Optometry · 2018Article
- Racial or Ethnic Health Disparities among Older Adults in Four Population Groups in South Africa.Annals of global health · 2018Article
- Clinical versus Evidence-based Rehabilitation Options for Post-stroke Visual Impairment.Neuro-ophthalmology (Aeolus Press) · 2017Review
- Association between Visual Impairment and Low Vision and Sleep Duration and Quality among Older Adults in South Africa.International journal of environmental research and public health · 2017Article
Corrections and comments
- Updated by
- Update of
Authors and funding
5 authors at 4 institutions in 4 countries.
Funding
Abstract
backgroundThe purpose of low-vision rehabilitation is to allow people to resume or to continue to perform daily living tasks, with reading being one of the most important. This is achieved by providing appropriate optical devices and special training in the use of residual-vision and low-vision aids, which range from simple optical magnifiers to high-magnification video magnifiers.
objectivesTo assess the effects of reading aids for adults with low vision. SEARCH
methodsWe searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 1), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE, (January 1950 to January 2013), EMBASE (January 1980 to January 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2013), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov/) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 31 January 2013. We searched the reference lists of relevant articles and used the Science Citation Index to find articles that cited the included studies and contacted investigators and manufacturers of low-vision aids. We handsearched the British Journal of Visual Impairment from 1983 to 1999 and the Journal of Visual Impairment and Blindness from 1976 to 1991. SELECTION CRITERIA: This review includes randomised and quasi-randomised trials in which any device or aid used for reading had been compared to another device or aid in people aged 16 or over with low vision as defined by the study investigators. DATA COLLECTION AND ANALYSIS: At least two authors independently assessed trial quality and extracted data. MAIN
resultsWe included nine small studies with a cross-over-like design (181 people overall) and one study with three parallel arms (243 participants) in the review. All studies reported the primary outcome, results for reading speed.Two studies including 92 participants found moderate- or low-quality evidence suggesting that reading speed is higher with stand-mounted electronic devices or electronic devices with the camera mounted in a 'mouse' than with optical magnifiers, which in these trials were generally stand-mounted or, less frequently, hand-held magnifiers or microscopic lenses. In another study of 20 participants there was moderate-quality evidence that optical devices are better than head-mounted electronic devices (four types).There was low-quality evidence from three studies (93 participants) that reading using head-mounted electronic devices is slower than with stand-based electronic devices. The technology of electronic devices may have changed and improved since these studies were conducted.One study suggested no difference between a diffractive spectacle-mounted magnifier and either refractive (15 participants) or aplanatic (15 participants) magnifiers.One study of 10 people suggested that several overlay coloured filters were no better and possibly worse than a clear filter.A parallel-arm study including 243 participants with age-related macular degeneration found that custom or standard prism spectacles were no different from conventional reading spectacles, although the data did not allow precise estimates of performance to be made. AUTHORS'
conclusionsThere is insufficient evidence on the effect of different types of low-vision aids on reading performance. It would be necessary to investigate which patient characteristics predict performance with different devices, including costly electronic devices. Better-quality research should also focus on assessing sustained long-term use of each device. Authors of studies testing several devices on the same person should consider design and reporting issues related to their sequential presentation and to the cross-over-like study design.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.