Evidence map›Paper›PMID 24127132›Full record

ArticleMagnetic resonance in medicine2014

Strategies for improved 3D small-tip fast recovery imaging.

Hao Sun, Jeffrey A Fessler, Douglas C Noll, Jon-Fredrik Nielsen

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hao SunDepartment of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan, USA.
Jeffrey A Fessler
Douglas C Noll
Jon-Fredrik Nielsen

Funding

MRI Parallel Excitation for Neuroimaging ApplicationsR01NS058576 · NINDS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NOLL, DOUGLAS C · 2008 to 2012
$3.0M
MRI Scanner for Functional Brain ImagingS10OD012240 · OD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NOLL, DOUGLAS C · 2012 to 2012
$2.0M
Improved Functional MRI Using Balanced SSFP and Parallel TransmissionR21EB012674 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI NIELSEN, JON-FREDRIK · 2011 to 2012
$404k
NIBIB NIH HHS R21 EB012674NIBIB NIH HHS R21EB012674NINDS NIH HHS R01 NS058576NINDS NIH HHS R01NS58576
6 · The paper itself

Abstract

purposeSmall-tip fast recovery (STFR) imaging is a recently proposed steady-state sequence that has similar image contrast as balanced steady-state free precession but has the potential to simultaneously remove banding artifacts and transient fluctuation. STFR relies on a "tip-up" radiofrequency (RF) pulse tailored to the accumulated phase during the free precession (data acquisition) interval, designed to bring spins back to the longitudinal axis, thereby preserving transverse magnetization as longitudinal magnetization for the next pulse repetition time. We recently proposed an RF-spoiled STFR sequence suitable for thin slab imaging, however, in many applications, e.g., functional magnetic resonance imaging or isotropic-resolution structural imaging, three-dimensional (3D) steady-state imaging is desirable. Unfortunately, 3D STFR imaging is challenging due to the need for 3D tailored RF pulses. Here, we propose new strategies for improved 3D STFR imaging, based on (i) unspoiled imaging, and (ii) joint design of nonslice-selective tip-down/tip-up RF pulses. THEORY AND

methodsWe derive an analytic signal model for the proposed unspoiled STFR sequence, and propose two strategies for designing the 3D tailored tip-down/tip-up RF pulses. We validate the analytic results using phantom and in vivo imaging experiments.

resultsOur analytic model and imaging experiments demonstrate that the proposed unspoiled STFR sequence is less sensitive to tip-up excitation error compared to the corresponding spoiled sequence, and may, therefore, be an attractive candidate for 3D imaging. The proposed "joint" RF pulse design method, in which we formulate the tip-down/tip-up RF pulse design task as a magnitude least squares problem, produces modest improvement over a simpler "Separate" design approach. Using the proposed unspoiled sequence and joint RF pulse design, we demonstrate proof-of-principle 3D STFR brain images with balanced steady-state free precession-like signal properties but with reduced banding.

conclusionUsing the proposed unspoiled sequence and joint RF pulse design, STFR brain images in a 3D region of interest with balanced steady-state free precession-like signal properties but with reduced banding can be obtained.

Indexed as

AlgorithmsBrainHumansImage EnhancementImage Interpretation, Computer-AssistedImaging, Three-DimensionalMagnetic Resonance ImagingPhantoms, ImagingReproducibility of ResultsSensitivity and Specificitybalanced steady-state free precessionbanding artifactpulse designsmall-tip fast recoverysteady-state magnetic resonance imaging

Identifiers

PMID24127132
PMCPMC4428120

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.