Analysis: New point-of-care blood glucose monitoring system for the hospital demonstrates satisfactory analytical accuracy using blood from critically ill patients--an important step toward improved blood glucose control in the hospital.

Jeffrey I Joseph

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Validation of Point-of-care Testing Device HemoCue® Glucose 201RT in Blood Glucose Estimation.Indian journal of community medicine : official publication of Indian Association of Preventive & Social Medicine · 2026
    Article
  2. The use of intramuscular glucagon to prevent IV glucose infusion in early neonatal hypoglycemia.Journal of perinatology : official journal of the California Perinatal Association · 2021
    Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jeffrey I JosephDepartment of Anesthesiology, Jefferson Medical College, Thomas Jefferson University, 1020 Locust St., JAH, Suite 565, Philadelphia, PA 19107. Jeffrey.Joseph@Jefferson.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patients managed in the intensive care units (ICUs) and general wards of the hospital experience a high incidence of hyperglycemia, hypoglycemia, and glycemic variability, despite significant hospital resources devoted to glucose control. Optimized glucose meters and monitoring systems are required to improve the safety and efficacy of insulin delivery and glucose control in the hospital. Safe insulin dosing requires timely and accurate glucose measurements, especially during dynamic changes in nutrition, insulin sensitivity, and physiological stress. In the current issue of Journal of Diabetes Science and Technology, Mitsios and coauthors describe the analytical accuracy of the new Accu-Check® Inform II blood glucose (BG) monitoring system commercialized by F. Hoffmann-La Roche Ltd. The point-of-care glucose meter achieved the desired degree of accuracy and precision, as defined by Clinical and Laboratory Standards Institute POCT12-A3 guidelines when evaluated using venous blood from 600 critically ill patients from multiple ICUs at two medical centers. Venous whole blood samples were used to obtain glucose meter results in duplicate. The remaining blood sample was centrifuged to obtain plasma for central hospital laboratory testing using the hexokinase method within 5 min of meter testing. A total of 98.8% of the 1200 Accu-Check Inform II meter's glucose values were within ± 12.5% (± 12 mg/dl) of the mean laboratory glucose value, and 99.8% were within ± 20% (± 20 mg/dl), thus meeting the Clinical and Laboratory Standards Institute criteria. Future studies are required to evaluate the clinical performance of the new BG monitoring system in the intended-use patient populations and critical care environments, using arterial, peripheral venous, central venous, and capillary blood samples.

Indexed as

Critical CarePoint-of-Care SystemsBlood GlucoseCritical IllnessHumansHyperglycemiaIntensive Care UnitsMonitoring, PhysiologicBlood Glucose

Identifiers

PMID24124956