Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

Udo Hoss, Erwin S Budiman, Hanqing Liu, Mark P Christiansen

Open access · greenAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it, 47 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Observational
  12. Article
  13. Article
  14. Flash Glucose Monitoring: The Future Is Here.Diabetes technology & therapeutics · 2017
    Article
  15. Article
  16. DTT: 19 Years and Counting ….Diabetes technology & therapeutics · 2017
    Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Udo HossAbbott Diabetes Care, 1360 South Loop Rd., Alameda, CA 94502. udo.hoss@abbott.com.
Erwin S Budiman
Hanqing Liu
Mark P Christiansen
Diabetes Care Center · USAbbott Diabetes Care (United States)Diablo Clinical Research · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGlucose monitoring systems using subcutaneously inserted sensors are currently labeled for up to 7 days of wear. In this study, we evaluated the feasibility of a 14-day wear duration using a modified version of the sensor found in the Freestyle Navigator™ continuous glucose monitoring system.

methodsSixty-two subjects with diabetes were enrolled in the study. One sensor per subject was inserted on the arm for a wear time of 14 days. Two different calibration algorithms were applied retrospectively, one that uses periodic sensor recalibrations and one without recalibrations. Sensor in vivo stability was determined by least square regression analysis using capillary blood glucose. Mean absolute relative difference (MARD) and mean relative difference were calculated. Consensus error grid analysis was performed by day and over the 14-day wear period to evaluate accuracy of both systems. The sensor insertion sites were inspected after sensor removal for skin reactions.

resultsSensor data from 55 subjects were used for the analysis. The accuracy metrics for the system with recalibration were calculated to MARD = 13.9% and 84.0% in zone A (error grid analysis). The system without recalibration performed significantly better, resulting in MARD of 12.2% and 88.0% in zone A (p < .0001). The maximum change of in vivo sensor sensitivity over the 14-day wear period was 2% per day. Two subjects reported pain during the first 5 days of sensor wear, and 1 subject reported itching at the sensor site. No further skin reactions were noticed.

conclusionsThe study shows that a 14-day sensor wear period is achievable. Moreover, sensors using "wired enzyme" technology showed excellent in vivo stability, with no significant sensitivity loss over the 14-day wear period.

Indexed as

AdolescentAdultAgedBiosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringDiabetes MellitusFemaleHumansMaleMiddle AgedSubcutaneous TissueYoung AdultBlood Glucose

Identifiers

PMID24124948
PMCPMC3876365
OpenAlexW2153612077

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.