Trial reportMagnetic resonance in medicine2014
Free-breathing cardiac MR stress perfusion with real-time slice tracking.
Trial report in Magnetic resonance in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- K-CC-MoCo: A Fast k-Space-Based Respiratory Motion Correction for Highly Accelerated First-Pass Perfusion Cardiovascular MR.Magnetic resonance in medicine · 2026Article
- Quantitative myocardial blood flow and perfusion reserve with exercise cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025Article
- Fast reconstruction of SMS bSSFP myocardial perfusion images using noise map estimation network (NoiseMapNet): a head-to-head comparison with parallel imaging and iterative reconstruction.Frontiers in cardiovascular medicine · 2024Article
- Free-breathing simultaneous native myocardial T1, T2 and T1ρ mapping with Cartesian acquisition and dictionary matching.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023Article
- Simultaneous multislice steady-state free precession myocardial perfusion with full left ventricular coverage and high resolution at 1.5 T.Magnetic resonance in medicine · 2022Article
- Simultaneous multi-slice steady-state free precession myocardial perfusion with iterative reconstruction and integrated motion compensation.European journal of radiology · 2022Article
- All-systolic first-pass myocardial rest perfusion at a long saturation time using simultaneous multi-slice imaging and compressed sensing acceleration.Magnetic resonance in medicine · 2021Article
- A fast navigator (fastNAV) for prospective respiratory motion correction in first-pass myocardial perfusion imaging.Magnetic resonance in medicine · 2021Article
- Combined simultaneous multislice bSSFP and compressed sensing for first-pass myocardial perfusion at 1.5 T with high spatial resolution and coverage.Magnetic resonance in medicine · 2020Article
- A swine model of infarct-related reentrant ventricular tachycardia: Electroanatomic, magnetic resonance, and histopathological characterization.Heart rhythm · 2016Article
- Design of parallel transmission radiofrequency pulses robust against respiration in cardiac MRI at 7 Tesla.Magnetic resonance in medicine · 2015Article
- A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2015Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeTo develop a free-breathing cardiac MR perfusion sequence with slice tracking for use after physical exercise.
methodsWe propose to use a leading navigator, placed immediately before each 2D slice acquisition, for tracking the respiratory motion and updating the slice location in real-time. The proposed sequence was used to acquire CMR perfusion datasets in 12 healthy adult subjects and 8 patients. Images were compared with the conventional perfusion (i.e., without slice tracking) results from the same subjects. The location and geometry of the myocardium were quantitatively analyzed, and the perfusion signal curves were calculated from both sequences to show the efficacy of the proposed sequence.
resultsThe proposed sequence was significantly better compared with the conventional perfusion sequence in terms of qualitative image scores. Changes in the myocardial location and geometry decreased by 50% in the slice tracking sequence. Furthermore, the proposed sequence had signal curves that are smoother and less noisy.
conclusionThe proposed sequence significantly reduces the effect of the respiratory motion on the image acquisition in both rest and stress perfusion scans.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials