ArticleAcademic radiology2013

Scatter correction associated with dedicated dual-source CT hardware improves accuracy of lung air measures.

Sean D Mobberley, Matthew K Fuld, Jered P Sieren, Andrew N Primak, Eric A Hoffman

Open access · greenAbstract read
In one paragraph

Article in Academic radiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Normal lung attenuation distribution and lung volume on computed tomography in a Chinese population.International journal of chronic obstructive pulmonary disease · 2019
    Article
  6. Article
  7. SPIROMICS Protocol for Multicenter Quantitative Computed Tomography to Phenotype the Lungs.American journal of respiratory and critical care medicine · 2016
    Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Sean D MobberleyDepartment of Radiology, Division of Physiological Imaging, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, CC 701 GH, University of Iowa Carver College of Medicine, Iowa City, IA 52241; Department of Biomedical Engineering, University of Iowa, Iowa City, IA.
Matthew K Fuld
Jered P Sieren
Andrew N Primak
Eric A Hoffman
University of Iowa · USUniversity of Iowa Hospitals and Clinics · US

Funding

Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI Brandi Janssen · 1990 to 2026
$40.5M
Image and Model Based Analysis of Lung DiseasesR01HL064368 · NHLBI · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED · 1999 to 2009
$15.6M
Multi-center Structural & Functional Quantitative CT Pulmonary PhenotypingR01HL112986 · NHLBI · UNIVERSITY OF IOWA · PI HOFFMAN, ERIC ALFRED · 2012 to 2016
$4.6M
NHLBI NIH HHS R01 HL064368NHLBI NIH HHS R01-HL-064368NHLBI NIH HHS R01 HL112986NIEHS NIH HHS P30 ES005605
6 · The paper itself

Abstract

RATIONALE AND

objectivesAccurate assessment of air density used to quantitatively characterize amount and distribution of emphysema in chronic obstructive pulmonary disease (COPD) subjects has remained challenging. Hounsfield units (HU) within tracheal air can be considerably less negative than -1000 HU. This study has sought to characterize the effects of improved scatter correction used in dual-source pulmonary computed tomography (CT). MATERIALS AND

methodsDual-source dual-energy (DSDE) and single-source (SS) scans taken at multiple energy levels and scan settings were acquired for quantitative comparison using anesthetized ovine (n = 6), swine (n = 13), and a lung phantom. Data were evaluated for the lung, inferior vena cava, and tracheal segments. To minimize the effect of cross-scatter, the phantom scans in the DSDE mode were obtained by reducing the current of one of the tubes to near zero.

resultsA significant shift in mean HU values in the tracheal regions of animals and the phantom is observed, with values consistently closer to -1000 HU in DSDE mode. HU values associated with SS mode demonstrated a positive shift of up to 32 HU. In vivo tracheal air measurements demonstrated considerable variability with SS scanning, whereas these values were more consistent with DSDE imaging. Scatter effects in the lung parenchyma differed from adjacent tracheal measures.

conclusionData suggest that the scatter correction introduced into the dual-energy mode of imaging has served to provide more accurate CT lung density measures sought to quantitatively assess the presence and distribution of emphysema in COPD subjects. Data further suggest that CT images, acquired without adequate scatter correction, cannot be corrected by linear algorithms given the variability in tracheal air HU values and the independent scatter effects on lung parenchyma.

Indexed as

AirScattering, RadiationTomography Scanners, X-Ray ComputedAnimalsEquipment DesignLungPhantoms, ImagingRadiography, ThoracicSheepSwineCOPDdual energyemphysemaLung densityquantitative CT

Identifiers

PMID24119345
PMCPMC3825679
OpenAlexW2111042342

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.