Evidence map›Paper›PMID 24107918›Full record

ArticleIEEE transactions on bio-medical engineering2014

Creation and characterization of an ultrasound and CT phantom for noninvasive ultrasound thermometry calibration.

Chun-Yen Lai, Dustin E Kruse, Katherine W Ferrara, Charles F Caskey

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Thermometry and ablation monitoring with ultrasound.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2015
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Chun-Yen Lai
Dustin E Kruse
Katherine W Ferrara
Charles F Caskey
University of California, Davis · US

Funding

Staff InvestigatorsP30CA093373 · NCI · UNIVERSITY OF CALIFORNIA DAVIS · PI Laura Marcu · 2002 to 2026
$84.9M
Ultrasound Imaging and Local Drug Delivery in TumorsR01CA103828 · NCI · UNIVERSITY OF CALIFORNIA DAVIS · PI FERRARA, KATHERINE W · 2004 to 2013
$10.4M
Ultrasound imaging and enhanced therapeutic responseR01CA134659 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FERRARA, KATHERINE W · 2009 to 2017
$4.4M
NCI NIH HHS P30 CA093373NCI NIH HHS R01 CA103828NCI NIH HHS R01CA103828NCI NIH HHS R01 CA134659NCI NIH HHS R01CA134659
6 · The paper itself

Abstract

Ultrasound thermometry provides noninvasive 2-D temperature monitoring, and in this paper, we have investigated the use of computed tomography (CT) radiodensity to characterize tissues to improve the accuracy of ultrasound thermometry. Agarose-based tissue-mimicking phantoms were created with glyceryl trioleate (a fat-mimicking material) concentration of 0%, 10%, 20%, 30%, 40%, and 50%. The speed of sound (SOS) of the phantoms was measured over a temperature range of 22.1-41.1 °C. CT images of the phantoms were acquired by a clinical dedicated breast CT scanner, followed by calculation of the Hounsfield units (HU). The phantom was heated with a therapeutic acoustic pulse (1.54 MHz), while RF data were acquired with a 10-MHz linear-array transducer. Two-dimensional speckle tracking was used to calculate the thermal strain offline. The tissue-dependent thermal strain parameter required for ultrasound thermometry was analyzed and correlated with CT radiodensity, followed by the validation of the temperature prediction. Results showed that the change in SOS with the temperature increase was opposite in sign between the 0%-10% and 20%-50% trioleate phantoms. The inverse of the tissue-dependent thermal strain parameter of the phantoms was correlated with the CT radiodensity (R(2) = 0.99). A blinded ultrasound thermometry study on phantoms with a trioleate range of 5%-35% demonstrated the capability to estimate the tissue-dependent thermal strain parameter and estimate temperature with error less than ~1 °C. In conclusion, CT radiodensity may provide a method for improving ultrasound thermometry in heterogeneous tissues.

Indexed as

Phantoms, ImagingCalibrationHumansModels, BiologicalThermometryTomography, X-Ray ComputedTrioleinTriolein

Identifiers

PMID24107918
PMCPMC3990871
OpenAlexW2056524722

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.