Evidence map›Paper›PMID 24107069›Full record

ArticleTissue engineering. Part C, Methods2014

Multimodal ultrasound-photoacoustic imaging of tissue engineering scaffolds and blood oxygen saturation in and around the scaffolds.

Yahfi Talukdar, Pramod Avti, John Sun, Balaji Sitharaman

Open access · greenAbstract read
In one paragraph

Article in Tissue engineering. Part C, Methods, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
3.7field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Imaging Biomaterial-Tissue Interactions.Trends in biotechnology · 2018
    Review
  11. Inverse Opal Scaffolds and Their Biomedical Applications.Advanced materials (Deerfield Beach, Fla.) · 2017
    Review
  12. Review
  13. Review
  14. Review
  15. Review
  16. Porous three-dimensional carbon nanotube scaffolds for tissue engineering.Journal of biomedical materials research. Part A · 2015
    Article
  17. Imaging strategies for tissue engineering applications.Tissue engineering. Part B, Reviews · 2015
    Review
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Yahfi Talukdar1 Department of Biomedical Engineering, Stony Brook University , Stony Brook, New York.
Pramod Avti
John Sun
Balaji Sitharaman
Stony Brook University · USFujiFilm VisualSonics (Canada) · CA

Funding

Nanotechnology-based Theranostic Technology for Bone Tissue EngineeringDP2OD007394 · OD · STATE UNIVERSITY NEW YORK STONY BROOK · PI SITHARAMAN, BALAJI · 2010 to 2010
$2.4M
NIH HHS 1DP2OD007394-01
6 · The paper itself

Abstract

Preclinical, noninvasive imaging of tissue engineering polymeric scaffold structure and/or the physiological processes such as blood oxygenation remains a challenge. In vitro or ex vivo, the widely used scaffold characterization modalities such as porosimetry, electron or optical microscopy, and X-ray microcomputed tomography have limitations or disadvantages-some are invasive or destructive, others have limited tissue penetration (few hundred micrometers) and/or show poor contrast under physiological conditions. Postmortem histological analysis, the most robust technique for the evaluation of neovascularization is obviously not appropriate for acquiring physiological or longitudinal data. In this study, we have explored the potential of ultrasound (US)-coregistered photoacoustic (PA) imaging as a noninvasive multimodal imaging modality to overcome some of the above challenges and/or provide complementary information. US-PA imaging was employed to characterize poly(lactic-co-glycolic acid) (PLGA) polymer scaffolds or single-walled carbon nanotube (SWCNT)-incorporated PLGA (SWCNT-PLGA) polymer scaffolds as well as blood oxygen saturation within and around the scaffolds. Ex vivo, PLGA and SWCNT-PLGA scaffolds were placed at 0.5, 2, and 6 mm depths in chicken breast tissues. PLGA scaffolds could be localized with US imaging, but generate no PA signal (excitation wavelengths 680 and 780 nm). SWCNT-PLGA scaffolds generated strong PA signals at both wavelengths due to the presence of the SWCNTs and could be localized with both US and PA imaging depths between 0.5-6 mm (lateral resolution = 90 μm, axial resolution = 40 μm). In vivo, PLGA and SWCNT-PLGA scaffolds were implanted in subcutaneous pockets at 2 mm depth in rats, and imaged at 7 and 14 days postsurgery. The anatomical position of both the scaffolds could be determined from the US images. Only SWCNT-PLGA scaffolds could be easily detected in the US-PA images. SWCNT-PLGA scaffolds had significant four times higher PA signal intensity compared with the surrounding tissue and PLGA scaffolds. In vivo blood oxygen saturation maps around and within the PLGA scaffolds could be obtained by PA imaging. There was no significant difference in oxygen saturation for the PLGA scaffolds at the two time points. The blood oxygen saturation maps complemented the histological analysis of neovascularization of the PLGA scaffolds.

Indexed as

Multimodal ImagingAnimalsLactic AcidMaleMicroscopy, Atomic ForceNanotubes, CarbonOxygenPhotoacoustic TechniquesPolyglycolic AcidPolylactic Acid-Polyglycolic Acid CopolymerRats, Sprague-DawleyTissue EngineeringTissue ScaffoldsUltrasonicsLactic AcidNanotubes, CarbonOxygenPolyglycolic AcidPolylactic Acid-Polyglycolic Acid Copolymer

Identifiers

PMID24107069
PMCPMC4005489
OpenAlexW1128887588

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.