Evidence map›Paper›PMID 24102393›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2013

Approaches for modelling interstitial ultrasound ablation of tumours within or adjacent to bone: theoretical and experimental evaluations.

Serena J Scott, Punit Prakash, Vasant Salgaonkar, Peter D Jones, Richard N Cam, Misung Han, Viola Rieke, E Clif Burdette, Chris J Diederich

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Article
  3. Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2021
    Article
  4. Article
  5. A Fully Actuated Robotic Assistant for MRI-Guided Precision Conformal Ablation of Brain Tumors.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2021
    Article
  6. Article
  7. Article
  8. Article
  9. Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2015
    Review
  10. Non-invasive measurement of the temperature rise in tissue surrounding a kidney stone subjected to ultrasonic propulsion.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2015
    Article
  11. Development of robust/predictive control strategies for image-guided ablative treatments using a minimally invasive ultrasound applicator.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2014
    Article
  12. Interstitial ultrasound ablation of vertebral and paraspinal tumours: parametric and patient-specific simulations.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2014
    Article
  13. Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2013
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Serena J ScottThermal Therapy Research Group, Department of Radiation Oncology, University of California , San Francisco , California .
Punit Prakash
Vasant Salgaonkar
Peter D Jones
Richard N Cam
Misung Han
Viola Rieke
E Clif Burdette
Chris J Diederich

Funding

Ultrasound Ablation on Bone Cancer Under CT FluoroscopyR44CA112852 · NCI · ACOUSTIC MEDSYSTEMS, INC. · PI BURDETTE, EVERETTE C · 2010 to 2012
$3.1M
Catheter-Based Ultrasound Hyperthermia System for 3D-Targeted Thermal TherapyR01CA122276 · NCI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI DIEDERICH, CHRIS JOHN · 2006 to 2009
$1.3M
MRI-Guided Cardiac Focused Ultrasound AblationR00HL097030 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI RIEKE, VIOLA · 2012 to 2015
$724k
NCI NIH HHS R01 CA122276NCI NIH HHS R44 CA112852NCI NIH HHS R44CA112852NHLBI NIH HHS R00 HL097030
6 · The paper itself

Abstract

purposeThe objectives of this study were to develop numerical models of interstitial ultrasound ablation of tumours within or adjacent to bone, to evaluate model performance through theoretical analysis, and to validate the models and approximations used through comparison to experiments.

methods3D transient biothermal and acoustic finite element models were developed, employing four approximations of 7-MHz ultrasound propagation at bone/soft tissue interfaces. The various approximations considered or excluded reflection, refraction, angle-dependence of transmission coefficients, shear mode conversion, and volumetric heat deposition. Simulations were performed for parametric and comparative studies. Experiments within ex vivo tissues and phantoms were performed to validate the models by comparison to simulations. Temperature measurements were conducted using needle thermocouples or magnetic resonance temperature imaging (MRTI). Finite element models representing heterogeneous tissue geometries were created based on segmented MR images.

resultsHigh ultrasound absorption at bone/soft tissue interfaces increased the volumes of target tissue that could be ablated. Models using simplified approximations produced temperature profiles closely matching both more comprehensive models and experimental results, with good agreement between 3D calculations and MRTI. The correlation coefficients between simulated and measured temperature profiles in phantoms ranged from 0.852 to 0.967 (p-value < 0.01) for the four models.

conclusionsModels using approximations of interstitial ultrasound energy deposition around bone/soft tissue interfaces produced temperature distributions in close agreement with comprehensive simulations and experimental measurements. These models may be applied to accurately predict temperatures produced by interstitial ultrasound ablation of tumours near and within bone, with applications toward treatment planning.

Indexed as

Models, TheoreticalUltrasonic TherapyAcousticsAnimalsBody TemperatureBone and BonesCattleFinite Element AnalysisMusclesNeoplasmsSwine

Identifiers

PMID24102393
PMCPMC4026292

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.