ArticleAdvanced functional materials2012
Encapsulating Elastically Stretchable Neural Interfaces: Yield, Resolution, and Recording/Stimulation of Neural Activity.
Article in Advanced functional materials, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Long-term potentiation and long-term depression are both impaired afterBiomedical physics & engineering express · 2025Article
- Multifunctional Nanomesh Enables Cellular-Resolution, Elastic Neuroelectronics.Advanced materials (Deerfield Beach, Fla.) · 2024Article
- Stretch-Induced Injury Affects Cortical Neuronal Networks in a Time- and Severity-Dependent Manner.Annals of biomedical engineering · 2024Article
- Article
- Gold-Plated Electrode with High Scratch Strength for Electrophysiological Recordings.Scientific reports · 2019Article
- High-Density Stretchable Electrode Grids for Chronic Neural Recording.Advanced materials (Deerfield Beach, Fla.) · 2018Article
- Multilayer Patterning of High Resolution Intrinsically Stretchable Electronics.Scientific reports · 2016Article
- Ultraflexible organic amplifier with biocompatible gel electrodes.Nature communications · 2016Article
- Alterations in Hippocampal Network Activity after In Vitro Traumatic Brain Injury.Journal of neurotrauma · 2015Article
- Article
- All-carbon-nanotube flexible multi-electrode array for neuronal recording and stimulation.Biomedical microdevices · 2014Article
- 25th anniversary article: A soft future: from robots and sensor skin to energy harvesters.Advanced materials (Deerfield Beach, Fla.) · 2014Review
- Biomaterials-based electronics: polymers and interfaces for biology and medicine.Advanced healthcare materials · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
A high resolution elastically stretchable microelectrode array (SMEA) to interface with neural tissue is described. The SMEA consists of an elastomeric substrate, such as poly(dimethylsiloxane) (PDMS), elastically stretchable gold conductors, and an electrically insulating encapsulating layer in which contact holes are opened. We demonstrate the feasibility of producing contact holes with 40 µm × 40 µm openings, show why the adhesion of the encapsulation layer to the underlying silicone substrate is weakened during contact hole fabrication, and provide remedies. These improvements result in greatly increased fabrication yield and reproducibility. An SMEA with 28 microelectrodes was fabricated. The contact holes (100 µm × 100 µm) in the encapsulation layer are only ~10% the size of the previous generation, allowing a larger number of microelectrodes per unit area, thus affording the capability to interface with a smaller neural population per electrode. This new SMEA is used to record spontaneous and evoked activity in organotypic hippocampal tissue slices at 0% strain before stretching, at 5 % and 10 % equibiaxial strain, and again at 0% strain after relaxation. The noise of the recordings increases with increasing strain. The frequency of spontaneous neural activity also increases when the SMEA is stretched. Upon relaxation, the noise returns to pre-stretch levels, while the frequency of neural activity remains elevated. Stimulus-response curves at each strain level are measured. The SMEA shows excellent biocompatibility for at least two weeks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.