Evidence map›Paper›PMID 24085634›Full record

SynthesisThe Cochrane database of systematic reviews2013

Flexible sigmoidoscopy versus faecal occult blood testing for colorectal cancer screening in asymptomatic individuals.

Øyvind Holme, Michael Bretthauer, Atle Fretheim, Jan Odgaard-Jensen, Geir Hoff

Open access · greenAbstract readSystematic ReviewNetwork Meta-Analysis
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 106 papers, 20 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
106citing papers in PubMed, 20 pooled it
9.9field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

106 citing papers in PubMed, 20 syntheses or guidelines pooled it, 221 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Guideline
  7. Pooled it
  8. Risk Prediction Models for Colorectal Cancer Incorporating Common Genetic Variants: A Systematic Review.Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology · 2019
    Pooled it
  9. Pooled it
  10. Pooled it
  11. Pooled it
  12. Atencion primaria · 2018
    Guideline
  13. Pooled it
  14. Colorectal Cancer Screening in Average Risk Populations: Evidence Summary.Canadian journal of gastroenterology & hepatology · 2016
    Pooled it
  15. Risk Prediction Models for Colorectal Cancer: A Systematic Review.Cancer prevention research (Philadelphia, Pa.) · 2016
    Pooled it
  16. Pooled it
  17. Guideline
  18. Screening with urinary dipsticks for reducing morbidity and mortality.The Cochrane database of systematic reviews · 2015
    Pooled it
  19. Pooled it
  20. Guideline

46 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Øyvind Holme
Michael Bretthauer
Atle Fretheim
Jan Odgaard-Jensen
Geir Hoff
Nasjonalt Kunnskapssenter for Helsetjenesten · NOSørlandet Sykehus · NOTelemark Hospital · NOUniversity of Oslo · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundColorectal cancer is the third most frequent cancer in the world. As the sojourn time for this cancer is several years and a good prognosis is associated with early stage diagnosis, screening has been implemented in a number of countries. Both screening with faecal occult blood test and flexible sigmoidoscopy have been shown to reduce mortality from colorectal cancer in randomised controlled trials. The comparative effectiveness of these tests on colorectal cancer mortality has, however, never been evaluated, and controversies exist over which test to choose.

objectivesTo compare the effectiveness of screening for colorectal cancer with flexible sigmoidoscopy to faecal occult blood testing. SEARCH

methodsWe searched MEDLINE and EMBASE (November 16, 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 11) and reference lists for eligible studies. SELECTION CRITERIA: Randomised controlled trials comparing screening with flexible sigmoidoscopy or faecal occult blood testing to each other or to no screening. Only studies reporting mortality from colorectal cancer were included. Faecal occult blood testing had to be repeated (annually or biennially). DATA COLLECTION AND ANALYSIS: Data retrieval and assessment of risk of bias were performed independently by two review authors. Standard meta-analyses using a random-effects model were conducted for flexible sigmoidoscopy and faecal occult blood testing (FOBT) separately and we calculated relative risks with 95% confidence intervals (CI). We used a Bayesian approach (a contrast-based network meta-analysis method) for indirect analyses and presented the results as posterior median relative risk with 95% credibility intervals. We assessed the quality of evidence using GRADE. MAIN

resultsWe identified nine studies comprising 338,467 individuals randomised to screening and 405,919 individuals to the control groups. Five studies compared flexible sigmoidoscopy to no screening and four studies compared repetitive guaiac-based FOBT (annually and biennially) to no screening. We did not consider that study risk of bias reduced our confidence in our results. We did not identify any studies comparing the two screening methods directly. When compared with no screening, colorectal cancer mortality was lower with flexible sigmoidoscopy (relative risk 0.72; 95% CI 0.65 to 0.79, high quality evidence) and FOBT (relative risk 0.86; 95% CI 0.80 to 0.92, high quality evidence). In the analyses based on indirect comparison of the two screening methods, the relative risk of dying from colorectal cancer was 0.85 (95% credibility interval 0.72 to 1.01, low quality evidence) for flexible sigmoidoscopy screening compared to FOBT. No complications occurred after the FOBT test itself, but 0.03% of participants suffered a major complication after follow-up. Among more than 60,000 flexible sigmoidoscopy screening procedures and almost 6000 work-up colonoscopies, a major complication was recorded in 0.08% of participants. Adverse event data should be interpreted with caution as the reporting of adverse effects was incomplete. AUTHORS'

conclusionsThere is high quality evidence that both flexible sigmoidoscopy and faecal occult blood testing reduce colorectal cancer mortality when applied as screening tools. There is low quality indirect evidence that screening with either approach reduces colorectal cancer deaths more than the other. Major complications associated with screening require validation from studies with more complete reporting of harms

Indexed as

Occult BloodSigmoidoscopyColonic NeoplasmsColonoscopyGuaiacHumansIndicators and ReagentsRandomized Controlled Trials as TopicRectal NeoplasmsGuaiacIndicators and Reagents

Identifiers

PMID24085634
PMCPMC9365065
OpenAlexW2103470058

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.