Evidence map›Paper›PMID 24083888›Full record

ArticleBMC cardiovascular disorders2013

The in vivo blood compatibility of bio-inspired small diameter vascular graft: effect of submicron longitudinally aligned topography.

Ruiming Liu, Yuansen Qin, Huijin Wang, Yong Zhao, Zuojun Hu, Shenming Wang

Open access · goldAbstract read
In one paragraph

Article in BMC cardiovascular disorders, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 35 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Challenges and strategies forBioactive materials · 2021
    Review
  8. Tissue-Engineered Heart Valves: A Call for Mechanistic Studies.Tissue engineering. Part B, Reviews · 2018
    Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Ruiming LiuDepartment of Vascular Surgery, First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, P, R, China. zuojunhu@hotmail.com.
Yuansen Qin
Huijin Wang
Yong Zhao
Zuojun Hu
Shenming Wang
Sun Yat-sen University · CNThe First Affiliated Hospital, Sun Yat-sen University · CNBeihang University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiovascular disease is the leading cause of deaths worldwide and the arterial reconstructive surgery remains the treatment of choice. Although large diameter vascular grafts have been widely used in clinical practices, there is an urgent need to develop a small diameter vascular graft with enhanced blood compatibility. Herein, we fabricated a small diameter vascular graft with submicron longitudinally aligned topography, which mimicked the tunica intima of the native arterial vessels and were tested in Sprague-Dawley (SD) rats.

methodsVascular grafts with aligned and smooth topography were prepared by electrospinning and were connected to the abdominal aorta of the SD rats to evaluate their blood compatibility. Graft patency and platelet adhesion were evaluated by color Doppler ultrasound and immunofluorescence respectively.

resultsWe observed a significant higher patency rate (p = 0.021) and less thrombus formation in vascular graft with aligned topography than vascular graft with smooth topography. However, no significant difference between the adhesion rates on both vascular grafts (smooth/aligned: 0.35‰/0.12‰, p > 0.05) was observed. Moreover, both vascular grafts had few adherent activated platelets on the luminal surface.

conclusionBionic vascular graft showed enhanced blood compatibility due to the effect of surface topography. Therefore, it has considerable potential for using in clinical application.

Indexed as

Blood Vessel ProsthesisAnimalsAorta, AbdominalBlood Vessel Prosthesis ImplantationPlatelet AdhesivenessRatsRats, Sprague-DawleyVascular Patency

Identifiers

PMID24083888
PMCPMC3850682
OpenAlexW2094568713

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.