Evidence map›Paper›PMID 24082870›Full record

ReviewHSS journal : the musculoskeletal journal of Hospital for Special Surgery2012

Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Henri Migaud, Sophie Putman, Antoine Combes, Charles Berton, Donatien Bocquet, Laurent Vasseur, Julien Girard

Abstract readReview
In one paragraph

Review in HSS journal : the musculoskeletal journal of Hospital for Special Surgery, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Hip Resurfacing: International Perspectives: Review Article.HSS journal : the musculoskeletal journal of Hospital for Special Surgery · 2017
    Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Henri MigaudDepartment of Orthopedic Surgery, Roger Salengro Hospital, University of Lille, 2 Av Oscar Lambret, 59037 Lille Cedex, France ; Orthopaedics Department, University of Lille, 2 avenue Oscar Lambret, 59037 Lille Cedex, France.
Sophie Putman
Antoine Combes
Charles Berton
Donatien Bocquet
Laurent Vasseur
Julien Girard
Hôpital Roger Salengro · FRUniversité de Lille · FRCentre Oscar Lambret · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRecent studies have recommended the discontinuation of metal-on-metal (MoM) components in total hip arthroplasty (THA) because of adverse effects reported with large-diameter MoM THA. This is despite favorable long-term results observed with 28 and 32 mm MoM bearings. QUESTIONS/PURPOSES: The aim of this study was to assess the value of calls for an end to MoM bearings as THA components. Specifically, we wish to address the risks associated with MoM bearings including adverse soft tissue reactions, metal ion release, and carcinogenic risk.

methodsThe study evaluates the arguments in the literature reporting on MoM (adverse soft tissue reactions, metal ion release, and carcinogenic risk) and the experience of the current authors who re-introduced these bearings in 1995. They are balanced by a benefit-risk review of the literature and the authors' experience with MoM use.

resultsAdverse reactions to metallic debris as well as metal ion release are predictable and can be prevented by adequate design (arc of coverage, clearance), metallurgy (forged instead of cast alloy, high-carbide content), and appropriate component orientation. There is no scientific evidence that carcinogenicity is increased in subjects with MoM hip prostheses. MoM articulations appear to be attractive allowing safe hip resurfacing, decreasing the risk of THA revision in active patients, and providing secure THA fixation with cement in cages in severely deformed hips. MoM bearings in women of child-bearing age are controversial, but long-term data on metallic devices in adolescents undergoing spinal surgery seem reassuring. DISCUSSION: Adequate selection of MoM articulations ensures their safe use. These articulations are sensitive to orientation. Fifteen years of safe experience with 28- and 32-mm bearings of forged alloy and high-carbide content is the main reason for retaining them in primary and revision THA.

Indexed as

chromiumcobalt, ionship resurfacingmetal-on-metal bearingmetal sensitivitypseudotumorswear

Identifiers

PMID24082870
PMCPMC3470659
OpenAlexW2021753824

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.