ArticleClinical orthopaedics and related research2014
High metal ion levels after use of the ASR™ device correlate with development of pseudotumors and T cell activation.
Article in Clinical orthopaedics and related research, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 37 citations in OpenAlex.
- The roles of essential trace elements in T cell biology.Journal of cellular and molecular medicine · 2024Review
- Periarticular metal hypersensitivity complications of hip bearings containing cobalt-chromium.EFORT open reviews · 2022Article
- Similar risk of cancer in patients younger than 55 years with or without a total hip arthroplasty (THA): a population- based cohort study on 18,771 exposed to THA and 87,683 controls.Acta orthopaedica · 2022Article
- The in vivo location of edge-wear in hip arthroplasties : combining pre-revision 3D CT imaging with retrieval analysis.Bone & joint research · 2021Article
- Cobalt-induced cardiomyopathy - do circulating cobalt levels matter?Bone & joint research · 2021Article
- Predictive factors affecting long-term survivorship of ASR metal-on-metal total hip arthroplasty.SICOT-J · 2021Article
- Peripheral Blood Lymphocyte Subpopulations in Patients Following Small Diameter Metal-On-Metal Total Hip Replacement at Long-Term Follow-Up.Journal of clinical medicine · 2020Article
- No generally increased risk of cancer after total hip arthroplasty performed due to osteoarthritis.International journal of cancer · 2020Article
- Follow-up of Metal-on-Metal Hip Replacements at a Large District Hospital and the Implementation of Medicines and Healthcare Products Regulatory Agency Guidelines: A Review of 297 Patients.Clinics in orthopedic surgery · 2019Article
- The 10-year outcomes of the ASR XL Acetabular System: a single-center experience from China.Journal of orthopaedic surgery and research · 2019Article
- Systemic cobaltism manifesting as oral mucosal discoloration and metallic gustation after metal-on-metal hip resurfacing.Arthroplasty today · 2018Article
- Correlation of serum metal ion levels with pathological changes of ARMD in failed metal-on-metal-hip-resurfacing arthroplasties.Archives of orthopaedic and trauma surgery · 2017Article
- Increased expression of inducible co-stimulator on CD4+ T-cells in the peripheral blood and synovial fluid of patients with failed hip arthroplasties.Bone & joint research · 2016Article
- CORR Insights(®): Early Lessons From a Worldwide, Multicenter, Followup Study of the Recalled Articular Surface Replacement Hip System.Clinical orthopaedics and related research · 2016Article
- No association between pseudotumors, high serum metal-ion levels and metal hypersensitivity in large-head metal-on-metal total hip arthroplasty at 5-7-year follow-up.Skeletal radiology · 2016Article
- Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management.Journal of functional biomaterials · 2015Review
- What are the current clinical issues in wear and tribocorrosion?Clinical orthopaedics and related research · 2014Review
- 11-Year outcomes in patients with metal-on-metal ASR hip arthroplasty.Journal of orthopaedicsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPseudotumors and immunologic alterations are reported in patients with elevated metal ion levels after resurfacing arthroplasty of the hip. A direct association of increased cobalt and chromium concentrations with the development of pseudotumors has not been established. QUESTIONS/PURPOSES: We hypothesized that (1) patients with higher blood cobalt and chromium concentrations are more likely to have pseudotumors develop, (2) elevated cobalt and chromium concentrations correlate with increased activation of defined T cell populations, and (3) elevated metal ion levels, small implant size, cup inclination angle, and patient age are risk factors for the development of pseudotumors.
methodsA single-surgeon cohort of 78 patients with 84 Articular Surface Replacement(®) implants was retrospectively investigated. Between 2006 and 2010, we performed 84 THAs using the Articular Surface Replacement(®) implant; this represented 2% (84/4950) of all primary hip replacements performed during that period. Of the procedures performed using this implant, we screened 77 patients (99%) at a mean of 43 months after surgery (range, 24-60 months). Seventy-one patients were investigated using ultrasound scanning, and cobalt and chromium concentrations in whole blood were determined by high-resolution inductively coupled plasma mass spectrometry. Differential analysis of lymphocyte subsets was performed by flow cytometry in 53 patients. Results of immunologic analyses were investigated separately for patients with and without pseudotumors. Pseudotumors were found in 25 hips (35%) and were more common in women than in men (p = 0.02). Multivariable regression analysis was performed to identify risk factors for the development of pseudotumors.
resultsCobalt and chromium concentrations were greater in patients with pseudotumors than in those without (cobalt, median 8.3 versus median 1.0 μg/L, p < 0.001; chromium, median 5.9 versus median 1.3 μg/L, p < 0.001). The percentage of HLA-DR(+)CD4(+) T cells was greater in patients with pseudotumors than in those without (p = 0.03), and the proportion of this lymphocyte subtype was positively correlated with cobalt concentrations (r = 0.3, p = 0.02). Multivariable regression analysis indicated that increasing cobalt levels were associated with the development of pseudotumors (p < 0.001), and that patients with larger implants were less likely to have them develop (p = 0.04); age and cup inclination were not risk factors.
conclusionsWe found a distinct association of elevated metal ion concentrations with the presence of pseudotumors and a correlation of increased cobalt concentrations with the proportion of activated T helper/regulator cells. Thus, the development of soft tissue masses after metal-on-metal arthroplasty could be accompanied by activation of T cells, indicating that this complication may be partly immunologically mediated. Further investigations of immunologic parameters in larger cohorts of patients with metal-on-metal arthroplasties are warranted. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials