Automated implant segmentation in cone-beam CT using edge detection and particle counting.
Article in International journal of computer assisted radiology and surgery, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Accuracy of robotic computer-assisted implant surgery in clinical studies: a systematic review and meta-analysis.BMC oral health · 2025Pooled it
- Systematic review and network meta-analysis of the accuracy of the orthodontic mini-implants placed in the inter-radicular space by image-guided-based techniques.BMC oral health · 2023Pooled it
- Metal implant segmentation in CT images based on diffusion model.BMC medical imaging · 2024Article
- Deep learning-based dental implant recognition using synthetic X-ray images.Medical & biological engineering & computing · 2022Article
- Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices.International journal of implant dentistry · 2021Article
- C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT.Physics in medicine and biology · 2020Article
- Known-component metal artifact reduction (KC-MAR) for cone-beam CT.Physics in medicine and biology · 2019Article
- Spinal pedicle screw planning using deformable atlas registration.Physics in medicine and biology · 2017Article
- Intraoperative detection and localization of cylindrical implants in cone-beam CT image data.International journal of computer assisted radiology and surgery · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo develop a fully automated, accurate and robust segmentation technique for dental implants on cone-beam CT (CBCT) images.
methodsA head-size cylindrical polymethyl methacrylate phantom was used, containing titanium rods of 5.15 mm diameter. The phantom was scanned on 17 CBCT devices, using a total of 39 exposure protocols. Images were manually thresholded to verify the applicability of adaptive thresholding and to determine a minimum threshold value (Tmin). A three-step automatic segmentation technique was developed. Firstly, images were pre-thresholded using Tmin. Next, edge enhancement was performed by filtering the image with a Sobel operator. The filtered image was thresholded using an iteratively determined fixed threshold (Tedge) and converted to binary. Finally, a particle counting method was used to delineate the rods. The segmented area of the titanium rods was compared to the actual area, which was corrected for phantom tilting.
resultsManual thresholding resulted in large variation in threshold values between CBCTs. After applying the edgeenhancing filter, a stable Tedge value of 7.5% was found. Particle counting successfully detected the rods for all but one device. Deviations between the segmented and real area ranged between -2.7 and +14.4mm(2) with an average absolute error of 2.8mm(2). Considering the diameter of the segmented area, submillimeter accuracy was seen for all but two data sets.
conclusionA segmentation technique was defined which can be applied to CBCT data for an accurate and fully automatic delineation of titanium rods. The technique was validated in vitro and will be further tested and refined on patient data.