ArticleSleep disorders2013
Accuracy of positive airway pressure device-measured apneas and hypopneas: role in treatment followup.
Article in Sleep disorders, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Socioeconomic status impacts blood pressure response to positive airway pressure treatment.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2022Trial
- Optimizing CPAP Adherence in Obstructive Sleep Apnea: A Narrative Review of Practical Strategies for Everyday Clinical Care.Healthcare (Basel, Switzerland) · 2026Review
- Auto-adjusting positive airway pressure: the fine line between engineering and medicine.Sleep & breathing = Schlaf & Atmung · 2025Review
- Normalisation of AHI Under Positive Pressure Therapy Does Not Necessarily Mean Control of Symptoms: A Comparison of the Effectiveness of APAP and CPAP on Daytime Sleepiness and Nocturnal Urination.Life (Basel, Switzerland) · 2025Article
- A Buccal Mucosal Oximeter Accurately Measures Arterial Oxyhemoglobin Saturation.Medical devices (Auckland, N.Z.) · 2025Article
- Article
- Use of polysomnography and home sleep apnea tests for the longitudinal management of obstructive sleep apnea in adults: an American Academy of Sleep Medicine clinical guidance statement.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2021Review
- Interpreting CPAP device respiratory indices in children.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2020Article
- A real-world comparison of apnea-hypopnea indices of positive airway pressure device and polysomnography.PloS one · 2017Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Improved data transmission technologies have facilitated data collected from positive airway pressure (PAP) devices in the home environment. Although clinicians' treatment decisions increasingly rely on autoscoring of respiratory events by the PAP device, few studies have specifically examined the accuracy of autoscored respiratory events in the home environment in ongoing PAP use. "PAP efficacy" studies were conducted in which participants wore PAP simultaneously with an Embletta sleep system (Embla, Inc., Broomfield, CO), which was directly connected to the ResMed AutoSet S8 (ResMed, Inc., San Diego, CA) via a specialized cable. Mean PAP-scored Apnea-Hypopnea Index (AHI) was 14.2 ± 11.8 (median: 11.7; range: 3.9-46.3) and mean manual-scored AHI was 9.4 ± 10.2 (median: 7.7; range: 1.2-39.3). Ratios between the mean indices were calculated. PAP-scored HI was 2.0 times higher than the manual-scored HI. PAP-scored AHI was 1.5 times higher than the manual-scored AHI, and PAP-scored AI was 1.04 of manual-scored AI. In this sample, PAP-scored HI was on average double the manual-scored HI. Given the importance of PAP efficacy data in tracking treatment progress, it is important to recognize the possible bias of PAP algorithms in overreporting hypopneas. The most likely cause of this discrepancy is the use of desaturations in manual hypopnea scoring.