Evidence map›Paper›PMID 24056744›Full record

ArticleLab on a chip2013

A microfluidic device for dry sample preservation in remote settings.

Stefano Begolo, Feng Shen, Rustem F Ismagilov

Open access · bronzeAbstract read
In one paragraph

Article in Lab on a chip, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 26 citations in OpenAlex.

  1. Review
  2. Review
  3. Microfluidic Contact Lenses.Small (Weinheim an der Bergstrasse, Germany) · 2018
    Article
  4. Review
  5. Article
  6. Stability of Proteins in Dried Blood Spot Biobanks.Molecular & cellular proteomics : MCP · 2017
    Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Individually addressable arrays of replica microbial cultures enabled by splitting SlipChips.Integrative biology : quantitative biosciences from nano to macro · 2014
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Stefano BegoloDivision of Chemistry and Chemical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125, USA. rustem.admin@caltech.edu.
Feng Shen
Rustem F Ismagilov
California Institute of Technology · US

Funding

Digital SlipChip Technology for POC and Resource-Limited Viral Load MeasurementsR01EB012946 · NIBIB · UNIVERSITY OF CHICAGO · PI ISMAGILOV, RUSTEM F · 2011 to 2014
$2.0M
NIBIB NIH HHS R01 EB012946NIBIB NIH HHS R01EB012946
6 · The paper itself

Abstract

This paper describes a microfluidic device for dry preservation of biological specimens at room temperature that incorporates chemical stabilization matrices. Long-term stabilization of samples is crucial for remote medical analysis, biosurveillance, and archiving, but the current paradigm for transporting remotely obtained samples relies on the costly "cold chain" to preserve analytes within biospecimens. We propose an alternative approach that involves the use of microfluidics to preserve samples in the dry state with stabilization matrices, developed by others, that are based on self-preservation chemistries found in nature. We describe a SlipChip-based device that allows minimally trained users to preserve samples with the three simple steps of placing a sample at an inlet, closing a lid, and slipping one layer of the device. The device fills automatically, and a pre-loaded desiccant dries the samples. Later, specimens can be rehydrated and recovered for analysis in a laboratory. This device is portable, compact, and self-contained, so it can be transported and operated by untrained users even in limited-resource settings. Features such as dead-end and sequential filling, combined with a "pumping lid" mechanism, enable precise quantification of the original sample's volume while avoiding overfilling. In addition, we demonstrated that the device can be integrated with a plasma filtration module, and we validated device operations and capabilities by testing the stability of purified RNA solutions. These features and the modularity of this platform (which facilitates integration and simplifies operation) would be applicable to other microfluidic devices beyond this application. We envision that as the field of stabilization matrices develops, microfluidic devices will be useful for cost-effectively facilitating remote analysis and biosurveillance while also opening new opportunities for diagnostics, drug development, and other medical fields.

Indexed as

Dried Blood Spot TestingHIV-1HumansMicrofluidic Analytical TechniquesPolymerase Chain ReactionRNA StabilityRNA, ViralRNA, Viral

Identifiers

PMID24056744
PMCPMC3851311
OpenAlexW2011147969

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.