ArticleDiabetes technology & therapeutics2013
The effect of congestive heart failure on sensor accuracy among hospitalized patients with type 2 diabetes.
Article in Diabetes technology & therapeutics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04149392 (Pilot Study for the Use of CGM for Post-discharge Diabetes Management Following a Hospitalization for Heart Failure or MI), which is not on this map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Pilot Study for the Use of CGM for Post-discharge Diabetes Management Following a Hospitalization for Heart Failure or MI
Who cites it
2 citing papers in PubMed, 8 citations in OpenAlex.
- Use of Continuous Glucose Monitoring in the Assessment and Management of Patients With Diabetes and Chronic Kidney Disease.Frontiers in endocrinology · 2022Review
- Glycemic variability during algorithmic titration of insulin among hospitalized patients with type 2 diabetes and heart failure.Journal of diabetes and its complicationsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
backgroundCongestive heart failure (CHF) features disturbances in the interstitial environment that may affect the accuracy of subcutaneous continuous glucose monitoring (CGM). SUBJECTS AND
methodsA pooled analysis of two studies of hospitalized patients with type 2 diabetes randomized to intravenous or subcutaneous insulin was conducted. One study enrolled patients with CHF exacerbation, whereas history of CHF was an exclusion criterion in the other. All patients wore a professional CGM device for at least 24 h. Intravenous insulin was administered according to the institution's nursing-run protocol (duration of 12 and 48 h in non-CHF and CHF protocols, respectively). Subcutaneous insulin was delivered similarly in both groups.
resultsSubjects with CHF (n=43) had higher admission glucose and hemoglobin A1c compared with non-CHF subjects (n=32), but the sensor glucose values were similar. Overall mean absolute relative difference (MARD) was similar between CHF and non-CHF subjects (0.11 vs. 0.08, respectively; P=0.12). MARD was higher in the 100-149 mg/dL (P=0.003) and >199 mg/dL (P = 0.02) strata among CHF subjects. Static glucose and continuous glucose error grid analyses favored the non-CHF group. In multivariable analyses, only glucose coefficient of variation and log sensor time were independent predictors of elevated overall MARD >0.10. After adjustment for other factors, only increasing log sensor time was a significant predictor of elevated MARD in the 100-149 mg/dL strata.
conclusionsAmong hospitalized subjects with type 2 diabetes, CHF exacerbation is not associated with lower sensor accuracy after adjustment for other factors, but this requires confirmation over a wider glucose range.