Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2014
Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.
Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed, 4 syntheses or guidelines pooled it, 49 citations in OpenAlex.
- 3D-printing techniques in a medical setting: a systematic literature review.Biomedical engineering online · 2016Pooled it
- No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015Pooled it
- No evidence of superiority in reducing outliers of component alignment for patient-specific instrumentation for total knee arthroplasty: a systematic review.Orthopaedic surgery · 2015Pooled it
- Systematic review of patient-specific instrumentation in total knee arthroplasty: new but not improved.Clinical orthopaedics and related research · 2015Pooled it
- Abnormal rate of intraoperative and postoperative implant positioning outliers using "MRI-based patient-specific" compared to "computer assisted" instrumentation in total knee replacement.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2016Trial
- Accuracy of Patient-Specific Instrument for Cylindrical Axis Implementation in Kinematically Aligned Total Knee Arthroplasty.Clinics in orthopedic surgery · 2023Article
- [Market overview: Robotic-assisted arthroplasty : Current robotic systems, learning curve and cost analysis].Orthopadie (Heidelberg, Germany) · 2022Review
- Concepts and techniques of a new robotically assisted technique for total knee arthroplasty: the ROSA knee system.Archives of orthopaedic and trauma surgery · 2021Review
- Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2021Article
- A clinical review of robotic navigation in total knee arthroplasty: historical systems to modern design.EFORT open reviews · 2021Review
- Advantages of patient-specific cutting guides with disposable instrumentation in total knee arthroplasty: a case control study.Journal of orthopaedic surgery and research · 2021Article
- Better accuracy and reproducibility of a new robotically-assisted system for total knee arthroplasty compared to conventional instrumentation: a cadaveric study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Article
- New Technologies in Knee Arthroplasty: Current Concepts.Journal of clinical medicine · 2020Review
- Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography-Based Navigation in Severe Post-High Tibial Osteotomy Valgus Collapse.Arthroplasty today · 2020Article
- Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.Archives of orthopaedic and trauma surgery · 2020Article
- Recent Trends, Technical Concepts and Components of Computer-Assisted Orthopedic Surgery Systems: A Comprehensive Review.Sensors (Basel, Switzerland) · 2019Review
- Automated segmentation of trabecular and cortical bone from proton density weighted MRI of the knee.Medical & biological engineering & computing · 2019Article
- Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
- Comparison between cylindrical axis-reference and articular surface-reference femoral bone cut for total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017Article
- Assessment of patient-specific instrumentation precision through bone resection measurements.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe introduction of patient-specific instruments (PSI) for guiding bone cuts could increase the incidence of malalignment in primary total knee arthroplasty. The purpose of this study was to assess the agreement between one type of patient-specific instrumentation (Zimmer PSI) and the pre-operative plan with respect to bone cuts and component alignment during TKR using imageless computer navigation.
methodsA consecutive series of 30 femoral and tibial guides were assessed in-theatre by the same surgeon using computer navigation. Following surgical exposure, the PSI cutting guides were placed on the joint surface and alignment assessed using the navigation tracker. The difference between in-theatre data and the pre-operative plan was recorded and analysed.
resultsThe error between in-theatre measurements and pre-operative plan for the femoral and tibial components exceeded 3° for 3 and 17% of the sample, respectively, while the error for total coronal alignment exceeded 3° for 27% of the sample.
conclusionThe present results indicate that alignment with Zimmer PSI cutting blocks, assessed by imageless navigation, does not match the pre-operative plan in a proportion of cases. To prevent unnecessary increases in the incidence of malalignment in primary TKR, it is recommended that these devices should not be used without objective verification of alignment, either in real-time or with post-operative imaging. Further work is required to identify the source of discrepancies and validate these devices prior to routine use. LEVEL OF EVIDENCE: II.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.