ArticleJournal of exposure science & environmental epidemiology
Indoor transformer stations and ELF magnetic field exposure: use of transformer structural characteristics to improve exposure assessment.
Article in Journal of exposure science & environmental epidemiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Effect of an Extremely Low-Frequency Electromagnetic Field on the Concentration of Salivary Immunoglobulin A.International journal of environmental research and public health · 2022Article
- Multidisciplinary and Nonpharmacological Management of Pain in Temporomandibular Disorders (TMDs).Pain research & management · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Previous studies have shown that populations of multiapartment buildings with indoor transformer stations may serve as a basis for improved epidemiological studies on the relationship between childhood leukaemia and extremely-low-frequency (ELF) magnetic fields (MFs). This study investigated whether classification based on structural characteristics of the transformer stations would improve ELF MF exposure assessment. The data included MF measurements in apartments directly above transformer stations ("exposed" apartments) in 30 buildings in Finland, and reference apartments in the same buildings. Transformer structural characteristics (type and location of low-voltage conductors) were used to classify exposed apartments into high-exposure (HE) and intermediate-exposure (IE) categories. An exposure gradient was observed: both the time-average MF and time above a threshold (0.4 μT) were highest in the HE apartments and lowest in the reference apartments, showing a statistically significant trend. The differences between HE and IE apartments, however, were not statistically significant. A simulation exercise showed that the three-category classification did not perform better than a two-category classification (exposed and reference apartments) in detecting the existence of an increased risk. However, data on the structural characteristics of transformers is potentially useful for evaluating exposure-response relationship.
Indexed as
Identifiers
24022671What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.