ArticleAnalytical chemistry2013
In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure.
Article in Analytical chemistry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed, 61 citations in OpenAlex.
- Review
- Advancements in Brain Research: The In Vivo/In Vitro Electrochemical Detection of Neurochemicals.Biosensors · 2024Review
- Techniques for Measurement of Serotonin: Implications in Neuropsychiatric Disorders and Advances in Absolute Value Recording Methods.ACS chemical neuroscience · 2023Review
- Dexamethasone-Enhanced Continuous Online Microdialysis for Neuromonitoring of OACS chemical neuroscience · 2023Article
- Article
- Optogenetic Stimulation of Midbrain Dopamine Neurons Produces Striatal Serotonin Release.ACS chemical neuroscience · 2022Article
- Tonic Serotonin MeasurementsAnalytical chemistry · 2021Article
- Implantable aptamer-field-effect transistor neuroprobes for in vivo neurotransmitter monitoring.Science advances · 2021Article
- Imaging in vivo acetylcholine release in the peripheral nervous system with a fluorescent nanosensor.Proceedings of the National Academy of Sciences of the United States of America · 2021Article
- A serotonin voltammetric biosensor composed of carbon nanocomposites and DNA aptamer.Mikrochimica acta · 2021Article
- Divalent Cation Dependence Enhances Dopamine Aptamer Biosensing.ACS applied materials & interfaces · 2021Article
- Recent Advances in In Vivo Neurochemical Monitoring.Micromachines · 2021Review
- Article
- Dexamethasone-Enhanced Microdialysis and Penetration Injury.Frontiers in bioengineering and biotechnology · 2020Review
- A rotating operant chamber for use with microdialysis.Journal of neuroscience methods · 2019Article
- Measurement of Basal Neurotransmitter Levels Using Convolution-Based Nonfaradaic Current Removal.Analytical chemistry · 2018Article
- In Vivo Ambient Serotonin Measurements at Carbon-Fiber Microelectrodes.Analytical chemistry · 2017Article
- Monitoring Dopamine Responses to Potassium Ion and Nomifensine by in Vivo Microdialysis with Online Liquid Chromatography at One-Minute Resolution.ACS chemical neuroscience · 2017Article
- Real-time measurement of small molecules directly in awake, ambulatory animals.Proceedings of the National Academy of Sciences of the United States of America · 2017Article
- Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods.Analytical chemistry · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Online monitoring of serotonin in striatal dialysate from freely moving rats was carried out for more than 16 h at 1 min time resolution using microdialysis coupled online to a capillary HPLC system operating at about 500 bar and 50 °C. Several aspects of the system were optimized toward robust, in vivo online measurements. A two-loop, eight-port rotary injection valve demonstrated better consistency of continuous injections than the more commonly used two-loop, 10-port valve. A six-port loop injector for introducing stimulating solutions (stimulus injector) was placed in-line between the syringe pump and microdialysis probe. We minimized solute dispersion by using capillary tubing (75 μm inside diameter, 70 cm long) for the probe inlet and outlet. In vitro assessment of concentration dispersion during transport with a 30 s time resolution showed that the dispersion standard deviation for serotonin was well within the desired system temporal resolution. Each 30 or 60 s measurement reflects the integral of the true time response over the measurement time. We have accounted for this mathematically in determining the concentration dispersion during transport. The delay time between a concentration change at the probe and its detection is 7 min. The timing of injections from the stimulus injector and the cycle time for the HPLC monitoring of the flow stream were controlled. The electrochemical detector contained a 13 μm spacer to minimize detector dead volume. During in vivo experiments, retention time and separation efficiency were stable and reproducible. There was no statistically significant change over 5.5 h in the electrochemical detector sensitivity factor for serotonin. Dialysate serotonin concentrations change significantly in response to a 120 mM K(+) stimulus. Release of serotonin evoked by a 10 min, 120 mM K(+) stimulation, but not for other K(+) stimuli, exhibited a reproducible, oscillating profile of dialysate serotonin concentration versus time. Infusion of fluoxetine, a serotonin uptake inhibitor, increased dialysate serotonin concentrations and stimulated release magnitude. Transient serotonin increases were observed in response to the stress associated with unexpected handling. This system is simple, efficient, reliable, and suitable for the study of serotonin neurochemistry associated with emotion and behavior.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.