Evidence map›Paper›PMID 24016065›Full record

ArticleACS nano2013

Fluorescent imaging of single nanoparticles and viruses on a smart phone.

Qingshan Wei, Hangfei Qi, Wei Luo, Derek Tseng, So Jung Ki, Zhe Wan, Zoltán Göröcs, Laurent A Bentolila, Ting-Ting Wu, Ren Sun and 1 more

Abstract read
In one paragraph

Article in ACS nano, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 121 papers.

0numbers the graph read from it
0cells of the map it votes in
121citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

121 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Portable sensing devices for smart healthcare and prevention of lead poisoning.Journal of the Chinese Medical Association : JCMA · 2023
    Review
  14. Article
  15. Review
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article

61 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Qingshan WeiElectrical Engineering Department, ‡Bioengineering Department, §California NanoSystems Institute (CNSI), ∥Department of Molecular and Medical Pharmacology, and ⊥Department of Chemistry and Biochemistry, University of California, Los Angeles (UCLA), California 90095, United States.
Hangfei Qi
Wei Luo
Derek Tseng
So Jung Ki
Zhe Wan
Zoltán Göröcs
Laurent A Bentolila
Ting-Ting Wu
Ren Sun
Aydogan Ozcan

Funding

Towards Mega-Throughput, Label-free Genomics and Proteomics: Revolutionizing MicrDP2OD006427 · OD · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI OZCAN, AYDOGAN · 2009 to 2009
$2.3M
NIH HHS DP2 OD006427NIH HHS DP2OD006427
6 · The paper itself

Abstract

Optical imaging of nanoscale objects, whether it is based on scattering or fluorescence, is a challenging task due to reduced detection signal-to-noise ratio and contrast at subwavelength dimensions. Here, we report a field-portable fluorescence microscopy platform installed on a smart phone for imaging of individual nanoparticles as well as viruses using a lightweight and compact opto-mechanical attachment to the existing camera module of the cell phone. This hand-held fluorescent imaging device utilizes (i) a compact 450 nm laser diode that creates oblique excitation on the sample plane with an incidence angle of ~75°, (ii) a long-pass thin-film interference filter to reject the scattered excitation light, (iii) an external lens creating 2× optical magnification, and (iv) a translation stage for focus adjustment. We tested the imaging performance of this smart-phone-enabled microscopy platform by detecting isolated 100 nm fluorescent particles as well as individual human cytomegaloviruses that are fluorescently labeled. The size of each detected nano-object on the cell phone platform was validated using scanning electron microscopy images of the same samples. This field-portable fluorescence microscopy attachment to the cell phone, weighing only ~186 g, could be used for specific and sensitive imaging of subwavelength objects including various bacteria and viruses and, therefore, could provide a valuable platform for the practice of nanotechnology in field settings and for conducting viral load measurements and other biomedical tests even in remote and resource-limited environments.

Indexed as

Cell PhoneNanoparticlesCytomegalovirusMicroscopy, Electron, ScanningMicroscopy, Fluorescence

Identifiers

PMID24016065
PMCPMC3951925

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.