ArticleJournal of the Association for Research in Otolaryngology : JARO2013
Directional plasticity rapidly improves 3D vestibulo-ocular reflex alignment in monkeys using a multichannel vestibular prosthesis.
Article in Journal of the Association for Research in Otolaryngology : JARO, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 31 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
First-in-Human Early Feasibility Study of Safety, Tolerability and Efficacy for a Multichannel Vestibular Implant in Individuals With Bilateral Severe-to-Profound Loss of Vestibular Sensation
Vestibular Implantation to Treat Adult-Onset Bilateral Vestibular Hypofunction
Vestibular Implantation in Older Adults
Long Term Outcomes After Vestibular Implantation
Who cites it
31 citing papers in PubMed, 41 citations in OpenAlex.
- Continuous vestibular implant stimulation partially restores eye-stabilizing reflexes.JCI insight · 2019Trial
- Effects of Electrode Position on Vestibular Implant Performance in Rhesus Macaque.Journal of the Association for Research in Otolaryngology : JARO · 2026Article
- Review
- Article
- [Recent progress in vestibular prosthesis].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2023Review
- The Next Challenges of Vestibular Implantation in Humans.Journal of the Association for Research in Otolaryngology : JARO · 2023Review
- Simultaneous activation of multiple vestibular pathways upon electrical stimulation of semicircular canal afferents.Journal of neurology · 2020Article
- Influence of systematic variations of the stimulation profile on responses evoked with a vestibular implant prototype in humans.Journal of neural engineering · 2020Article
- [Current status and new progress of vestibular assistant systems].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2020Review
- Electrical Vestibular Stimulation in Humans: A Narrative Review.Audiology & neuro-otology · 2020Review
- Binocular 3D otolith-ocular reflexes: responses of chinchillas to prosthetic electrical stimulation targeting the utricle and saccule.Journal of neurophysiology · 2020Article
- Virtual Rhesus Labyrinth Model Predicts Responses to Electrical Stimulation Delivered by a Vestibular Prosthesis.Journal of the Association for Research in Otolaryngology : JARO · 2019Article
- Nonhuman primate vestibuloocular reflex responses to prosthetic vestibular stimulation are robust to pulse timing errors caused by temporal discretization.Journal of neurophysiology · 2019Article
- The Dynamics of Prosthetically Elicited Vestibulo-Ocular Reflex Function Across Frequency and Context in the Rhesus Monkey.Frontiers in neuroscience · 2018Article
- Analysis of Vestibular Labyrinthine Geometry and Variation in the Human Temporal Bone.Frontiers in neuroscience · 2018Article
- Plasticity within excitatory and inhibitory pathways of the vestibulo-spinal circuitry guides changes in motor performance.Scientific reports · 2017Article
- The Vestibular Implant Input Interacts with Residual Natural Function.Frontiers in neurology · 2017Article
- Recent surgical options for vestibular vertigo.GMS current topics in otorhinolaryngology, head and neck surgery · 2017Review
- Galvanic Vestibular Stimulation: Cellular Substrates and Response Patterns of Neurons in the Vestibulo-Ocular Network.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2016Article
- Plasticity within non-cerebellar pathways rapidly shapes motor performance in vivo.Nature communications · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
Bilateral loss of vestibular sensation can be disabling. We have shown that a multichannel vestibular prosthesis (MVP) can partly restore vestibular sensation as evidenced by improvements in the 3-dimensional angular vestibulo-ocular reflex (3D VOR). However, a key challenge is to minimize misalignment between the axes of eye and head rotation, which is apparently caused by current spread beyond each electrode's targeted nerve branch. We recently reported that rodents wearing a MVP markedly improve 3D VOR alignment during the first week after MVP activation, probably through the same central nervous system adaptive mechanisms that mediate cross-axis adaptation over time in normal individuals wearing prisms that cause visual scene movement about an axis different than the axis of head rotation. We hypothesized that rhesus monkeys would exhibit similar improvements with continuous prosthetic stimulation over time. We created bilateral vestibular deficiency in four rhesus monkeys via intratympanic injection of gentamicin. A MVP was mounted to the cranium, and eye movements in response to whole-body passive rotation in darkness were measured repeatedly over 1 week of continuous head motion-modulated prosthetic electrical stimulation. 3D VOR responses to whole-body rotations about each semicircular canal axis were measured on days 1, 3, and 7 of chronic stimulation. Horizontal VOR gain during 1 Hz, 50 °/s peak whole-body rotations before the prosthesis was turned on was <0.1, which is profoundly below normal (0.94 ± 0.12). On stimulation day 1, VOR gain was 0.4-0.8, but the axis of observed eye movements aligned poorly with head rotation (misalignment range ∼30-40 °). Substantial improvement of axis misalignment was observed after 7 days of continuous motion-modulated prosthetic stimulation under normal diurnal lighting. Similar improvements were noted for all animals, all three axes of rotation tested, for all sinusoidal frequencies tested (0.05-5 Hz), and for high-acceleration transient rotations. VOR asymmetry changes did not reach statistical significance, although they did trend toward slight improvement over time. Prior studies had already shown that directional plasticity reduces misalignment when a subject with normal labyrinths views abnormal visual scene movement. Our results show that the converse is also true: individuals receiving misoriented vestibular sensation under normal viewing conditions rapidly adapt to restore a well-aligned 3D VOR. Considering the similarity of VOR physiology across primate species, similar effects are likely to occur in humans using a MVP to treat bilateral vestibular deficiency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.