Evidence map›Paper›PMID 24013822›Full record

ArticleJournal of the Association for Research in Otolaryngology : JARO2013

Directional plasticity rapidly improves 3D vestibulo-ocular reflex alignment in monkeys using a multichannel vestibular prosthesis.

Chenkai Dai, Gene Y Fridman, Bryce Chiang, Mehdi A Rahman, Joong Ho Ahn, Natan S Davidovics, Charles C Della Santina

4 registry-linked trialsOpen access · bronzeAbstract read
In one paragraph

Article in Journal of the Association for Research in Otolaryngology : JARO, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
3.4field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02725463 naactive not recruitingnot on this mapstarted 2016, after this paper: background citation

First-in-Human Early Feasibility Study of Safety, Tolerability and Efficacy for a Multichannel Vestibular Implant in Individuals With Bilateral Severe-to-Profound Loss of Vestibular Sensation

TypeinterventionalSponsorJohns Hopkins UniversityRan2016 to 2028Enrolled30ConditionsOther Disorders of Vestibular Function, Bilateral, Bilateral Vestibular Deficiency (BVD), Gentamicin Ototoxicity, Labyrinth DiseasesArmsLabyrinth Devices MVI™ Multichannel Vestibular Implant
NCT05674786 narecruitingnot on this mapstarted 2023, after this paper: background citation

Vestibular Implantation to Treat Adult-Onset Bilateral Vestibular Hypofunction

TypeinterventionalSponsorJohns Hopkins UniversityRan2023 to 2027Enrolled8ConditionsOther Disorders of Vestibular Function, Bilateral, Bilateral Vestibular Deficiency (BVD), Gentamicin Ototoxicity, Labyrinth DiseasesArmsLabyrinth Devices MVI™ Multichannel Vestibular Implant System
NCT05676944 narecruitingnot on this mapstarted 2023, after this paper: background citation

Vestibular Implantation in Older Adults

TypeinterventionalSponsorJohns Hopkins UniversityRan2023 to 2028Enrolled15ConditionsOther Disorders of Vestibular Function, Bilateral, Bilateral Vestibular Deficiency (BVD), Gentamicin Ototoxicity, Labyrinth DiseasesArmsLabyrinth Devices MVI™ Multichannel Vestibular Implant System
NCT06500975 narecruitingnot on this mapstarted 2024, after this paper: background citation

Long Term Outcomes After Vestibular Implantation

TypeinterventionalSponsorJohns Hopkins UniversityRan2024 to 2029Enrolled32ConditionsBilateral Vestibular Hypofunction, Bilateral Vestibular Deficiency, Bilateral Vestibulopathy, Gentamicin OtotoxicityArmsLabyrinth Devices MVI™ Multichannel Vestibular Implant System
3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 41 citations in OpenAlex.

  1. Trial
  2. Effects of Electrode Position on Vestibular Implant Performance in Rhesus Macaque.Journal of the Association for Research in Otolaryngology : JARO · 2026
    Article
  3. Review
  4. Article
  5. [Recent progress in vestibular prosthesis].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2023
    Review
  6. The Next Challenges of Vestibular Implantation in Humans.Journal of the Association for Research in Otolaryngology : JARO · 2023
    Review
  7. Article
  8. Article
  9. [Current status and new progress of vestibular assistant systems].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2020
    Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Recent surgical options for vestibular vertigo.GMS current topics in otorhinolaryngology, head and neck surgery · 2017
    Review
  19. Galvanic Vestibular Stimulation: Cellular Substrates and Response Patterns of Neurons in the Vestibulo-Ocular Network.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2016
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Chenkai DaiDepartment of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, USA, cdai4@jhmi.edu.
Gene Y Fridman
Bryce Chiang
Mehdi A Rahman
Joong Ho Ahn
Natan S Davidovics
Charles C Della Santina
Johns Hopkins Medicine · USJohns Hopkins University · US

Funding

The Physiology of Vestibular CompensationR01DC002390 · NIDCD · JOHNS HOPKINS UNIVERSITY · PI Kathleen E Cullen · 1995 to 2026
$10.7M
The Histology CoreP30DC005211 · NIDCD · JOHNS HOPKINS UNIVERSITY · PI FUCHS, PAUL ALBERT · 2002 to 2016
$9.1M
Training Program in Hearing and BalanceT32DC000023 · NIDCD · JOHNS HOPKINS UNIVERSITY · PI CULLEN, KATHLEEN E · 1989 to 2025
$8.7M
Electrical Stimulation to Restore Three Dimensional Vestibular SensationR01DC009255 · NIDCD · JOHNS HOPKINS UNIVERSITY · PI DELLA SANTINA, CHARLES C · 2008 to 2018
$5.7M
Stimulation model and experiments for a vestubular prosthesis.F32DC009917 · NIDCD · JOHNS HOPKINS UNIVERSITY · PI FRIDMAN, GENE YEVGENY · 2008 to 2009
$66k
NIDCD NIH HHS 5F32DC009917NIDCD NIH HHS F32 DC009917NIDCD NIH HHS P30 DC005211NIDCD NIH HHS R01 DC002390NIDCD NIH HHS R01 DC009255NIDCD NIH HHS R01DC009255NIDCD NIH HHS R01DC2390NIDCD NIH HHS T32 DC000023
6 · The paper itself

Abstract

Bilateral loss of vestibular sensation can be disabling. We have shown that a multichannel vestibular prosthesis (MVP) can partly restore vestibular sensation as evidenced by improvements in the 3-dimensional angular vestibulo-ocular reflex (3D VOR). However, a key challenge is to minimize misalignment between the axes of eye and head rotation, which is apparently caused by current spread beyond each electrode's targeted nerve branch. We recently reported that rodents wearing a MVP markedly improve 3D VOR alignment during the first week after MVP activation, probably through the same central nervous system adaptive mechanisms that mediate cross-axis adaptation over time in normal individuals wearing prisms that cause visual scene movement about an axis different than the axis of head rotation. We hypothesized that rhesus monkeys would exhibit similar improvements with continuous prosthetic stimulation over time. We created bilateral vestibular deficiency in four rhesus monkeys via intratympanic injection of gentamicin. A MVP was mounted to the cranium, and eye movements in response to whole-body passive rotation in darkness were measured repeatedly over 1 week of continuous head motion-modulated prosthetic electrical stimulation. 3D VOR responses to whole-body rotations about each semicircular canal axis were measured on days 1, 3, and 7 of chronic stimulation. Horizontal VOR gain during 1 Hz, 50 °/s peak whole-body rotations before the prosthesis was turned on was <0.1, which is profoundly below normal (0.94 ± 0.12). On stimulation day 1, VOR gain was 0.4-0.8, but the axis of observed eye movements aligned poorly with head rotation (misalignment range ∼30-40 °). Substantial improvement of axis misalignment was observed after 7 days of continuous motion-modulated prosthetic stimulation under normal diurnal lighting. Similar improvements were noted for all animals, all three axes of rotation tested, for all sinusoidal frequencies tested (0.05-5 Hz), and for high-acceleration transient rotations. VOR asymmetry changes did not reach statistical significance, although they did trend toward slight improvement over time. Prior studies had already shown that directional plasticity reduces misalignment when a subject with normal labyrinths views abnormal visual scene movement. Our results show that the converse is also true: individuals receiving misoriented vestibular sensation under normal viewing conditions rapidly adapt to restore a well-aligned 3D VOR. Considering the similarity of VOR physiology across primate species, similar effects are likely to occur in humans using a MVP to treat bilateral vestibular deficiency.

Indexed as

Neural ProsthesesProsthesis ImplantationAdaptation, PhysiologicalAnimalsMacaca mulattaReflex, Vestibulo-OcularRotationSemicircular CanalsVestibule, Labyrinth

Identifiers

PMID24013822
PMCPMC3825024
OpenAlexW2072283644

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.