ArticleElectrophoresis2014
Joule heating effects on particle immobilization in insulator-based dielectrophoretic devices.
Article in Electrophoresis, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- Dielectrophoresis-Enhanced Graphene Field-Effect Transistors for Nano-Analyte Sensing.ACS applied materials & interfaces · 2025Article
- Protein Manipulation via Dielectrophoresis: Theoretical Principles and Emerging Microfluidic Platforms.Micromachines · 2025Review
- Innovative CMOS-fabricated dielectrophoretic chip: application of 3D TiN nano-electrode arrays with adjustable electrode spacing in sperm capture.Frontiers in bioengineering and biotechnology · 2025Article
- Development of a DC-Biased AC-Stimulated Microfluidic Device for the Electrokinetic Separation of Bacterial and Yeast Cells.Biosensors · 2024Article
- Switching Separation Migration Order by Switching Electrokinetic Regime in Electrokinetic Microsystems.Biosensors · 2024Article
- Recent advances and challenges in temperature monitoring and control in microfluidic devices.Electrophoresis · 2023Review
- M-TUBE enables large-volume bacterial gene delivery using a high-throughput microfluidic electroporation platform.PLoS biology · 2022Article
- Protein Albumin Manipulation and Electrical Quantification of Molecular Dielectrophoresis Responses for Biomedical Applications.Micromachines · 2022Review
- Study on non-bioparticles andRSC advances · 2020Article
- Localized Dielectric Loss Heating in Dielectrophoresis Devices.Scientific reports · 2019Article
- Low frequency cyclical potentials for fine tuning insulator-based dielectrophoretic separations.Biomicrofluidics · 2019Article
- A review of polystyrene bead manipulation by dielectrophoresis.RSC advances · 2019Review
- Three-Dimensional Reservoir-Based Dielectrophoresis (rDEP) for Enhanced Particle Enrichment.Micromachines · 2018Article
- Assessment of Sub-Micron Particles by Exploiting Charge Differences with Dielectrophoresis.Micromachines · 2017Article
- Refinement of insulator-based dielectrophoresis.The Analyst · 2017Article
- Modelling of electrokinetic phenomena for capture of PEGylated ribonuclease A in a microdevice with insulating structures.Biomicrofluidics · 2016Article
- Refinement of current monitoring methodology for electroosmotic flow assessment under low ionic strength conditions.Biomicrofluidics · 2016Article
- Dynamic dielectrophoresis model of multi-phase ionic fluids.PloS one · 2015Article
- Protein dielectrophoresis and the link to dielectric properties.Bioanalysis · 2015Review
- Temporal and spatial temperature measurement in insulator-based dielectrophoretic devices.Analytical chemistry · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In this work, the temperature effects due to Joule heating obtained by application of a direct current electric potential were investigated for a microchannel with cylindrical insulating posts employed for insulator-based dielectrophoresis. The conductivity of the suspending medium, the local electric field, and the gradient of the squared electric field, which directly affect the magnitude of the dielectrophoretic force exerted on particles, were computationally simulated employing COMSOL Multiphysics. It was observed that a temperature gradient is formed along the microchannel, which redistributes the conductivity of the suspending medium leading to an increase of the dielectrophoretic force toward the inlet of the channel while decreasing toward the outlet. Experimental results are in good agreement with simulations on the particle-trapping zones anticipated. This study demonstrates the importance of considering Joule heating effects when designing insulator-based dielectrophoresis systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.