ArticleAnalytical chemistry2013
Photolithographic fabrication of microapertures with well-defined, three-dimensional geometries for suspended lipid membrane studies.
Article in Analytical chemistry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Review
- Silicon Nitride-Based Micro-Apertures Coated with Parylene for the Investigation of Pore Proteins Fused in Free-Standing Lipid Bilayers.Membranes · 2022Article
- Parallel Recordings of Transmembrane hERG Channel Currents Based on Solvent-Free Lipid Bilayer Microarray.Micromachines · 2021Article
- Rapid lipid bilayer membrane formation on Parylene coated apertures to perform ion channel analyses.Biomedical microdevices · 2020Article
- Rapid Prototyping of Soft Lithography Masters for Microfluidic Devices Using Dry Film Photoresist in a Non-Cleanroom Setting.Micromachines · 2019Article
- Mechanically stable solvent-free lipid bilayers in nano- and micro-tapered apertures for reconstitution of cell-free synthesized hERG channels.Scientific reports · 2017Article
- Bioinspired Assemblies and Plasmonic Interfaces for Electrochemical Biosensing.Journal of electroanalytical chemistry (Lausanne, Switzerland) · 2016Article
- Emerging trends in precision fabrication of microapertures to support suspended lipid membranes for sensors, sequencing, and beyond.Analytical and bioanalytical chemistry · 2015Article
- Ion channel probes for scanning ion conductance microscopy.Langmuir : the ACS journal of surfaces and colloids · 2014Article
- Monitoring charge flux to quantify unusual ligand-induced ion channel activity for use in biological nanopore-based sensors.Analytical chemistry · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Robust and high-density biosensors incorporating suspended lipid membranes require microfabricated apertures that can be readily integrated into complex analysis systems. Apertures with well-defined, three-dimensional geometries enable the formation of suspended lipid membranes and facilitate reduced aperture size compared to vertical-walled apertures. Unfortunately, existing methods of producing apertures with well-defined, three-dimensional geometries are based on complex and expensive fabrication procedures, some of which yield apertures in excessively fragile thin-film materials. Here, we describe a microfabrication method utilizing incline and rotate lithography that achieves sloped-wall microapertures in SU-8 polymer substrates with precision control of the aperture diameter, substrate thickness, and wall angle. This approach is simple, is of low cost, and is readily scaled up to allow highly reproducible parallel fabrication. The effect of the incident angle of UV exposure and the size of photomask features on the aperture geometry were investigated, yielding aperture diameters as small as 7 μm and aperture wall angles ranging from 8° to 36° measured from the normal axis. Black lipid membranes were suspended across the apertures and showed normalized conductance values of 0.02-0.05 pS μm(-2) and breakdown voltages of 400-600 mV. The functionality of the resulting sloped-wall microapertures was validated via measurement of reconstituted α-hemolysin activity and the voltage-gated channel activity of alamethicin.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.