Evidence map›Paper›PMID 23981339›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2013

Reproducibility of cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance for measuring left ventricular strains, torsion, and synchrony in mice.

Christopher M Haggerty, Sage P Kramer, Cassi M Binkley, David K Powell, Andrea C Mattingly, Richard Charnigo, Frederick H Epstein, Brandon K Fornwalt

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed, 1 pooled it
4.2field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 1 synthesis or guideline pooled it, 40 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Myofiber strain in healthy humans using DENSE and cDTI.Magnetic resonance in medicine · 2021
    Article
  10. Article
  11. Article
  12. Article
  13. Comparison of left ventricular strains and torsion derived from feature tracking and DENSE CMR.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2018
    Article
  14. Article
  15. Article
  16. Article
  17. Impaired right ventricular contractile function in childhood obesity and its association with right and left ventricular changes: a cine DENSE cardiac magnetic resonance study.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2017
    Article
  18. Article
  19. Article
  20. Using a respiratory navigator significantly reduces variability when quantifying left ventricular torsion with cardiovascular magnetic resonance.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Christopher M HaggertyDepartments of Pediatrics, Physiology and Medicine, University of Kentucky, Lexington, KY, USA. bkf@gatech.edu.
Sage P Kramer
Cassi M Binkley
David K Powell
Andrea C Mattingly
Richard Charnigo
Frederick H Epstein
Brandon K Fornwalt
University of Kentucky · USUniversity of Virginia · US

Funding

The role of IKKß in linking obesity to adipose tissue inflammation and adipogeneP20GM103527 · NIGMS · UNIVERSITY OF KENTUCKY · PI CASSIS, LISA A · 2012 to 2017
$13.7M
Kentucky Center for Clinical and Translational ScienceUL1TR000117 · NCATS · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2012 to 2015
$13.3M
KENTUCKY CENTER FOR CLINICAL AND TRANSLATIONAL SCIENCEUL1RR033173 · NCRR · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2011 to 2011
$3.5M
Clinical Scholars In Cardiovascular ScienceT32HL091812 · NHLBI · UNIVERSITY OF KENTUCKY · PI SMYTH, SUSAN S. · 2008 to 2018
$2.3M
Exploring the Role of Dyssynchrony in Pediatric Heart Disease with MRIDP5OD012132 · OD · UNIVERSITY OF KENTUCKY · PI FORNWALT, BRANDON K · 2012 to 2016
$2.2M
Kentucky Center for Clinical and Translational ScienceKL2TR000116 · NCATS · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2012 to 2015
$1.9M
Kentucky Center for Clinical and Translational ScienceKL2RR033171 · NCRR · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2011 to 2011
$302k
Kentucky Center for Clinical and Translational ScienceTL1RR033172 · NCRR · UNIVERSITY OF KENTUCKY · PI KERN, PHILIP A · 2011 to 2011
$161k
NCATS NIH HHS KL2 TR000116NCATS NIH HHS UL1 TR000117NCRR NIH HHS KL2 RR033171NCRR NIH HHS TL1 RR033172NCRR NIH HHS UL1 RR033173NCRR NIH HHS UL1RR033173NHLBI NIH HHS 5T32HL91812-05NHLBI NIH HHS T32 HL091812NIGMS NIH HHS 8 P20 GM103527-05NIGMS NIH HHS P20 GM103527NIH HHS 1DP5OD012132-01
6 · The paper itself

Abstract

backgroundAdvanced measures of cardiac function are increasingly important to clinical assessment due to their superior diagnostic and predictive capabilities. Cine DENSE cardiovascular magnetic resonance (CMR) is ideal for quantifying advanced measures of cardiac function based on its high spatial resolution and streamlined post-processing. While many studies have utilized cine DENSE in both humans and small-animal models, the inter-test and inter-observer reproducibility for quantification of advanced cardiac function in mice has not been evaluated. This represents a critical knowledge gap for both understanding the capabilities of this technique and for the design of future experiments. We hypothesized that cine DENSE CMR would show excellent inter-test and inter-observer reproducibility for advanced measures of left ventricular (LV) function in mice.

methodsFive normal mice (C57BL/6) and four mice with depressed cardiac function (diet-induced obesity) were imaged twice, two days apart, on a 7T ClinScan MR system. Images were acquired with 15-20 frames per cardiac cycle in three short-axis (basal, mid, apical) and two long-axis orientations (4-chamber and 2-chamber). LV strain, twist, torsion, and measures of synchrony were quantified. Images from both days were analyzed by one observer to quantify inter-test reproducibility, while inter-observer reproducibility was assessed by a second observer's analysis of day-1 images. The coefficient of variation (CoV) was used to quantify reproducibility.

resultsLV strains and torsion were highly reproducible on both inter-observer and inter-test bases with CoVs ≤ 15%, and inter-observer reproducibility was generally better than inter-test reproducibility. However, end-systolic twist angles showed much higher variance, likely due to the sensitivity of slice location within the sharp longitudinal gradient in twist angle. Measures of synchrony including the circumferential (CURE) and radial (RURE) uniformity of strain indices, showed excellent reproducibility with CoVs of 1% and 3%, respectively. Finally, peak measures (e.g., strains) were generally more reproducible than the corresponding rates of change (e.g., strain rate).

conclusionsCine DENSE CMR is a highly reproducible technique for quantification of advanced measures of left ventricular cardiac function in mice including strains, torsion and measures of synchrony. However, myocardial twist angles are not reproducible and future studies should instead report torsion.

Indexed as

Magnetic Resonance Imaging, CineMyocardial ContractionVentricular Function, LeftAnimalsBiomechanical PhenomenaDisease Models, AnimalMiceMice, Inbred C57BLObesityObserver VariationPredictive Value of TestsReproducibility of ResultsStress, MechanicalTorsion, MechanicalVentricular Dysfunction, Left

Identifiers

PMID23981339
PMCPMC3765995
OpenAlexW2128744715

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.